Electrical System
Diode Assemblies
Groundsmaster 3500 machines use diodes that plug
into the wiring harness (Fig. 16). Location of the diodes
is under the control console.
Diode D1 is used on both diesel and gasoline powered
units. Diode D1 is used to protect the PTO solenoid
valve coil from reverse polarity.
Diodes D2 and D3 are used on gasoline powered units
only. Diode D2 is used to protect the circuits from voltage
spikes when the engine starter solenoid is de- ener-
gized. Diode D3 protects the engine start relay circuit
from reverse polarity.
The diode assemblies can be identified by a black color
and a diode symbol on the end of the diode assembly
body. Refer to the engine wire harness drawing in Chap-
ter 9 in this manual for additional information on diode
assembly location.
Testing
The diodes can be individually tested using a digital
multimeter (diode test or ohms setting) and the table be-
low.
Multimeter
Red Lead (+)
on Terminal
Multimeter
Black Lead (- )
on Terminal
Continuity
Female
Male
YES
Male
Female
NO
1. Diode
2. Male terminal
3. Female terminal
4. End of diode body
1
2
3
4
Figure 16
CAN- bus Termination Resistor (Gasoline Engines Only)
System communication between electrical components
on Groundsmaster 3500- G machines is accomplished
on a CAN- bus communication system. Two (2) special-
ly designed, twisted cables form the bus for the network
used on the machine. These wires provide the data
pathways between machine components. At the end of
one of the cables is a 120 ohm termination resistor.
The CAN- bus termination resistor plugs into the main
wire harness under the operator’s control panel (see
Chapter 9 - Foldout Drawings in this manual). The res-
istor can be accessed by removing the control panel
cover. The termination resistor and the wire harness
connector have blue inserts to identify the proper loca-
tion for the termination resistor. The resistor also has a
center keyway to prevent it from plugging into the wrong
wire harness connector.
IMPORTANT: The termination resistor is required
for proper electrical system operation.
Termination Resistor Test
Remove the termination resistor from the main wire har-
ness (Fig. 17). Test the resistor using a digital multimeter
(ohms setting). There should be
120 ohms
resistance
across terminals A and B of the termination resistor.
Figure 17
Termination
Resistor
A
B
C
Keyway
Ele
ctric
al
Sy
st
em
Summary of Contents for Groundsmaster 3500 30807
Page 1: ...Form No 14209SL Rev C Groundsmaster 3500 Models 30807 and 30809 Original Instructions EN ...
Page 4: ...NOTES _ ...
Page 6: ...Groundsmaster 3500 This page is intentionally blank ...
Page 8: ...Groundsmaster 3500 This page is intentionally blank ...
Page 14: ...Page 1 6 Safety Groundsmaster 3500 This page is intentionally blank ...
Page 22: ...Groundsmaster 3500 D Page 3 2 Kubota Diesel Engine This page is intentionally left blank ...
Page 38: ...Groundsmaster 3500 D Page 3 18 Kubota Diesel Engine This page is intentionally left blank ...
Page 40: ...Groundsmaster 3500 G Page 4 2 Kubota Gasoline Engine This page is intentionally left blank ...
Page 194: ...Groundsmaster 3500 Hydraulic System Page 5 136 This page is intentionally blank ...
Page 230: ...Groundsmaster 3500 Page 6 36 Electrical System This page is intentionally blank ...
Page 259: ...Groundsmaster 3500 Cutting Decks Page 8 7 This page is intentionally blank Cutting Decks ...
Page 268: ...Groundsmaster 3500 Cutting Decks Page 8 16 This page is intentionally blank ...
Page 272: ...Groundsmaster 3500 Cutting Decks Page 8 20 This page is intentionally blank ...
Page 279: ...Page 9 7 Harness Drawing Groundsmaster 3500 D SERIAL NUMBER ABOVE 314000001 ...
Page 283: ...Page 9 11 Harness Drawing Groundsmaster 3500 G ...