Groomer Cover (Counter Rotating Groomer Drive)
On eFlex machines with the counter rotating groomer, the groomer cover
includes a handle which engages and disengages the groomer drive. When the
handle is rotated toward the front of the machine, the groomer is engaged.
Removing the Groomer Cover (Counter Rotating Groomer Drive)
1. Park machine on level surface. Turn key switch to the O
FF
position and
remove key from the switch. Ensure that the traction lever is in the N
EUTRAL
position.
2. Disconnect the battery pack; refer to
Connecting the Lithium Battery Pack
(page 8–3)
.
3. Ensure that the handle on groomer cover is rotated toward front of machine
so that the groomer drive is engaged.
g228144
Figure 186
1.
Groomer cover assembly
3.
Gasket
2.
Flange-head screw (5 each)
4.
Handle
4. Remove groomer cover assembly from machine (
):
A. Remove 5 flange-head screws that secure groomer cover assembly to
right drive plate.
B. Remove groomer cover assembly and gasket from machine. Discard
gasket.
5. If necessary, remove shaft from groomer cover (
):
A. Loosen set screw on top of shaft and slide handle from shaft.
B. Remove retaining ring and thrust washer from shaft.
C. Remove plunger detent from groomer cover.
D. Slide shaft out of groomer cover. Remove and discard O-ring from shaft.
6. Remove grease from inside groomer cover and right drive plate on cutting
unit. Thoroughly clean and inspect all groomer drive components.
Greensmaster
®
eFlex 1800, 2100 and 2120
Page 8–7
Belt Driven Groomer: Service and Repairs
12189SL Rev E