background image

Boom-Width Settings

The boom-width settings are pre-populated at the
manufacturing plant (

Figure 9

).

Calibration Screen

To access the Calibration screen, press button 2 on the Main
Menu screen (

Figure 6

) until you reach Calibration, and press

button 4 to select Calibration.

Note:

Pressing button 5 at any time cancels calibrations.

If you do so, the machine automatically uses the current
calibration rates.

Figure 21

Flow Calibration

Perform the flow calibration before using the machine for the
first time, if you change the nozzles, or as needed.

Note:

It is recommended to perform a nozzle-uniformity

test before starting a Flow Calibration.

1.

Set the machine into manual mode, close the
boom-sections-bypass valve, turn on the sprayer pump,
turn off agitation, and set the engine to full throttle.

2.

To access the Flow screen, press button 4 on the
Calibrate screen (

Figure 21

to select Flow.

3.

Fill the sprayer tank with a minimum of 700 L (150 US
gallons) of water and apply the parking brake.

4.

Press button 2 to move to the next step and to view the
Select Nozzle Color screen.

5.

Use button 3 and button 4 to select the nozzle that
you are using.

6.

Press button 2 to move to the next step and to view the
To Proceed screen.

7.

Press button 2 to move to the next step and to view the
15 Second Catch Test screen.

Note:

It is recommended to start the 15 second catch

test at 2.75 bar (40 psi), then adjust from there.
All boom sections must be on when performing the
catch test.

8.

Start at 2.75 bar (40 psi) and use the application-rate
switch to adjust the spray pressure so a catch test yields
the volume displayed for the selected nozzle color.

9.

Press button 2 to move to the next step.

10.

Turn on all boom sections, turn on the master boom,
and press button 2 to begin calibration.

Note:

Calibration takes several minutes.

Note:

As the machine sprays, the InfoCenter displays

the volume of fluid that it is counting.

Important:

Do not turn off the pump or any

booms during calibration.

11.

If the calibration is successful, a Calibration Successful
screen appears; press button 5 to exit.

12.

If the calibration is not successful, a Calibration Failed
screen appears with the reasoning behind why the
calibration failed; press button 5 to exit and restart the
calibration.

Speed Calibration

1.

Ensure that the tires are properly inflated; refer to the

Operator’s Manual

.

2.

To access the Speed screen, press button 2 on the
Calibrate screen until you reach Speed, then press
button 4 (

Figure 21

) to select Speed.

3.

Fill the sprayer tank with a minimum of 700 L (150 US
gallons) of water and apply the parking brake.

4.

Press button 2 to move to the next step and to view the
Speed Calibration screen.

5.

Mark off the desired distance before proceeding to the
next screen.

6.

Press button 2 to move to the next step.

7.

Press button 3 to increase the desired distance or press
button 4 to decrease the desired distance (

Figure 22

).

Note:

If you choose to cancel the calibration by

pressing button 5, the system automatically defaults to
the previously-stored distance.

10

 

Summary of Contents for 41642

Page 1: ...ard against personal contact with a chemical There may be more than 1 chemical used and information on each chemical should be assessed Refuse to operate or work on the sprayer if this information is...

Page 2: ...er 4 Remove the clamps gaskets and manifold coupler Figure 1 Note Retain the clamps 5 Install the flow meter and 2 flow meter gaskets using the clamps that you just removed Figure 1 6 Remove the trans...

Page 3: ...Switch 2 Plug 10 Install the switch into the hole Figure 4 11 Beneath the dashboard connect the wire harness to the switch then connect it to the machine wire harness Note The connector on the machine...

Page 4: ...2 13 14 15 G035692 Figure 5 1 Master boom switch indicator on 5 Tank volume indicator US gallons 9 Selected application rate boost rate indicator on 13 Active application rate gpa 2 Right boom section...

Page 5: ...at Figure 5 Selected Application Rate Boost Rate Indicator The selected application rate boost rate indicator displays when either the selected application rate and or the boost rate are active Figure...

Page 6: ...usly to select Rate 1 or press and hold buttons 4 and 5 simultaneously to select Rate 2 Note From the Home screen press and hold buttons 1 and 5 simultaneously to apply boost rate Boost is active only...

Page 7: ...3 Press button 1 or 2 until you reach the desired unit and then press button 4 to select this unit English mph gallons acre Turf mph gallons 100 ft SI metric kph liter hectare Change the InfoCenter d...

Page 8: ...5 Enter PIN 3 Digit 3 3 From the PIN Settings screen press button 4 to select PIN Entry and to turn the PIN on or off Figure 16 Figure 16 Change the InfoCenter PIN as follows 1 Press button 2 on the...

Page 9: ...Enter your new PIN using buttons 1 to 4 and press button 5 when you complete your new PIN Figure 19 Figure 19 1 Digit 1 4 Digit 4 2 Digit 2 5 Enter PIN 3 Digit 3 6 Confirm your new PIN using buttons 1...

Page 10: ...ctions must be on when performing the catch test 8 Start at 2 75 bar 40 psi and use the application rate switch to adjust the spray pressure so a catch test yields the volume displayed for the selecte...

Page 11: ...a Calibration Successful screen appears press button 5 to exit 12 If the calibration is not successful a Calibration Failed screen appears with the reasoning behind why the calibration failed press b...

Page 12: ...ect About Figure 26 This screen displays the model number and serial number of your machine G034285 Figure 26 InfoCenter Spray Area Screens From the Home screen press and hold button 5 to open the men...

Page 13: ...ub area 4 Volume sprayed in the active sub area US gallons 2 Area sprayed in the active sub area acres 5 Select the previous sub area hold the button to reset area and volume sprayed for the active su...

Page 14: ...isories Condition Code Qualifier Display Text Start Prevented 2 Pump switch active To start turn pump off Start Prevented 3 Not in NEUTRAL To start return traction pedal to neutral Start Prevented 4 O...

Page 15: ...Parameter Status 503 A value is outside the range of accepted values Parameter status invalid data defaults used Booms Turned Off 802 Speed dropped Booms turned off stopped or moving too slowly 15...

Page 16: ......

Reviews: