INPUTS
OUTPUTS
Function
Power
ON
In
Neutral
Start ON
Brake
ON
PTO ON
In Seat
Hi Temp
Backlap
Start
ETR
PTO
Start
—
—
+
O
O
—
O
O
+
+
O
Run (Off
Unit)
—
—
O
O
O
O
O
O
O
+
O
Run (On
Unit)
—
O
O
—
O
—
O
O
O
+
O
Mow
—
O
O
—
—
—
O
O
O
+
+
Backlap
—
—
O
O
—
O
O
—
O
+
+
Hi Temp
—
O
—
O
O
O
To troubleshoot, turn the key to the On position. Identify
the specific function that is not operating properly and work
across the logic chart. Inspect the condition of each of the
input LEDs to ensure it matches the logic chart.
If the input LEDs are correct, check the output LEDs. If the
output LEDs are illuminated but the device is not energized,
measure the available voltage at the output device, continuity
of the disconnected device, and potential voltage on the
ground circuit (floating ground). Repairs will vary depending
on your findings.