F.
Remove the spring-clevis pin, rotate the
turnbuckle clockwise 1-additional turn, and insert
the spring-clevis pin (
).
5.
Repeat steps
through
for the other
traction-control linkage.
Hydraulic System
Maintenance
Maintaining the Auxiliary
Hydraulic System
Hydraulic oil type:
AW-32 hydro oil
Checking the Auxiliary Hydraulic Fluid
Level
Service Interval:
Every 50 hours
1.
Park the machine on a level surface.
2.
Lower the tines to the ground.
3.
Stop the engine, set the parking brake, remove the key,
and wait for all moving parts to stop before leaving the
operating position.
4.
Remove the console pad; refer to
Console Pad (page 28)
.
5.
Clean area around hydraulic reservoir cap (
).
Figure 58
1.
Cold
oil level
2.
Hot
oil level
6.
Remove the cap and check hydraulic oil level in the
reservoir (
).
Note:
The hydraulic oil level should cover the word
Cold
that is embossed into the baffle of the reservoir.
7.
If necessary, add the specified hydraulic oil to the
reservoir until the oil covers the
Cold
oil level on the
baffle (
).
Note:
The baffle ion the reservoir is labeled
Hot
and
Cold
. You will fill the reservoir to the appropriate level
depending upon the temperature of the oil. The oil
level will vary with the temperature of the oil. The
Cold
level shows the level of the oil when it is at 24°C
(75°F). The
Hot
level shows the level of oil when it
is at 107°C (225°F).
44