M841 M2 M2000
Counter spindle cleaning -> Air with Timer.
M841 M4 M2000
Counter spindle cleaning -> Oil with Timer.
M890
Auxiliary spindle.
(HF, analog,…) (rotation activation) (speed in M200)
M891
Auxiliary spindle.
(HF, analog,…) (rotation deactivation)
M901 M1 M0
Deactivation of output 1 on optional socket 1.
M901 M1 M1
Activation of output 1 on optional socket 1.
M901 M2 M0
Deactivation of output 2 on optional socket 1.
M901 M2 M1
Activation of output 2 on optional socket 1.
M901 M3 My
Optional socket 1 configuration.
M901 M4
Optional socket 1 input check.
(pulse 100 ms)
M902 M1 M0
Deactivation of output 1 on optional socket 2.
M902 M1 M1
Activation of output 1 on optional socket 2.
M902 M2 M0
Deactivation of output 2 on optional socket 2.
M902 M2 M1
Activation of output 2 on optional socket 2.
M902 M3 My
Optional socket 2 configuration.
M902 M4
Optional socket 2 input check.
(Activation of cutting liquid by counter spindle)
M90x M1 M0
Deactivation of output 1 on optional socket 1.
(X=number of optional socket)
M90x M1 M1
Activation of output 1 on optional socket 1.
(X=number of optional socket)
M90x M2 M0
Deactivation of output 2 on optional socket 1.
(X=number of optional socket)
M90x M2 M1
Activation of output 2 on optional socket X (X=number of optional socket)
M90x M3 My
Optional socket X configuration (X=number of optional socket)
M90x M4
Optional socket X input control (pulse 100 ms)(X=number of optional socket)
M1103
Rotation S11.
(clockwise)
M1104
Rotation S11.
(counterclockwise)
M1105
Stop S11.
M1203
Rotation S12.
(clockwise)
M1204
Rotation S12.
(counterclockwise)
M1205
Stop S12.
M2103
Rotation S21.
(clockwise)
M2104
Rotation S21.
(counterclockwise)
M2105
Stop S21.