INSTALLATION − DECO 7e / 10e − 0017
300440 en − 01/07
Chap. 4.4.1 /8
Version 0017
XS94
XS60
(2)
QS0
XS42
XS1
106
LOCATION OF ELEMENTS
Ref.
Description
QS0
Main Switch
XS60
Fire protection system
XS94
Barfeeder socket, fixed
XS94
Barfeeder socket, fixed
XS42
Interface socket for pump, cooling.
(1)
Reserve
(2)
Socket for eternet
TM1
Autotransformer (if required)
TC1
Mains voltage transformer inside lathe’s enclosure
XS1
Single phase current socket 230V 50Hz
4.4.1 Installation Characteristics
Feature
Notes
Data
Lathe power:
Average effective power:
(acc. to lathe application)
5 kW approx.
Installed power:
8 kVA approx.
Mains tolerances:
rated voltage:
frequency:
+/−10%
+/−1 Hz for 50/60 Hz
Main circuit-breaker:
at machine input
25 A
Δ
See also your instructions: SAFETY REGULATIONS DECO 7a / 10a