11
3. The version of the software
program of the card (for ex-
ample 4-6).
SETTING OF THE BATTERY
CHECK CARD
The setting of the battery
check card can be:
GE 24 (check card set for AGM
batteries) or Pb 24 (check card
set for lead batteries).
The machine is supplied with
the battery check card set
for the installed batteries.
To modify this setting, it is
necessary to:
1. Switch the machine off and
then back on.
2. Immediately after having
switched on, when on the
display (1) the writing Pb24
appears, press and hold the
push buttons (2) and (3) until
the display starts to blink.
3. When the display starts to
blink, release the push buttons
(2) and (3) and press once the
push button (3).
4. The display ‘GE24’ starts to
blink.
5. When the display stops
blinking, the setting is
modified.
To change from GEL to Lead-
Acid, repeat the procedure
pressing button (2) instead of
button (3).
SWITCHING ON THE
MACHINE
To start any function of the
machine, rotate the key
switch clock-wise. Rotating it
counterclockwise will turn off
all functions (see “LEGEND
PANEL OF CONTROLS”).
WHEN THE MACHINE IS
SWITCHED ON, ON THE
DISPLAY (1) APPEAR IN
ORDER THE FOLLOWING
INFORMATION:
1. The machine model (for
example AdL).
2. The setting of the battery
check card which can be: GE
24 (check card set for AGM
batteries). or Pb 24 (check
card set for lead batteries).
ATTENTION:
ATTENTION:
4. The batteries charge level
indicator is digital and remains
fixed on the display. The
battery charge level starts
from -100-, which indicates
the 100% of the total charge
and decreases from 100 to
10. When the charge level
reaches -20-, the display starts
blinking, so you are about the
end of working.
When the indication
-10- appears blinking,
automatically the brushes
stop, while the suction
continues to work. When
there are four lines blinking,
the suction will also stop
automatically. The traction
system remains functioning to
enable movement to transfer
the machine to the place
provided for the tank emptying
and for the recharge of the
batteries.
As the machine is a 24V
model, do not set the batteries
at 36V.