EN - 29
T100 DES
Radio hand-held transmitter (optional)
Start button (functional process in pulse OPEN operating mode /
pulse CLOSE):
•
Initial pulse generation:
Drive starts and moves the door to the end position OPEN
or CLOSE that is set.
•
Pulse generation during the process:
Door stops.
•
New pulse:
Door continues moving in the opposite direction.
AR operation:
•
Pulse generation: Door opens
½ door opening button
•
Function as for the start button, however, the door only
approaches the ½ door opening that is set.
Light button:
•
The light function is a continuous light, which can be
switched irrespective of the "ON / OFF" door action.
Key switch function (optional)
The control is provided with an input for a key switch. This allows
you to activate various functions using menu item 50, "Key switch
function".
Door action status display
Display State
Upper end position OPEN reached
Door end position has not been reached
Lower end position CLOSE reached
Representation of the door opening frequency
Representation of the door closing frequency
8
Troubleshooting
Error
State
Diagnosed cause
E02
Door neither opens
nor closes. Safety in-
put J4.3/4 triggered
Check status of the peripherals at
J4.3/4.
E03
Door neither opens
nor closes. Wicket
door open
Close wicket door.
E05
Door neither opens
nor closes. Safety
switch has triggered
Connection line 8k2 strip dam-
aged, check slack rope switch.
E06
Door reverses / does
not close
Closing edge has triggered.
Check menu item 35.
E07
Door reverses / does
not close
Photoelectric sensor has
triggered. Check menu item 36.
E08
Door neither opens
nor closes. DES
safety circuit drive
open
Manual override actuated, Motor,
thermal switch has triggered, mo-
tor overload or blockage.
E09
Door neither opens
nor closes
No door end position pro-
grammed.
Program door end position under
menu items 30 + 31.
E10
Menu item 36 set to
value 3 or 4
Completely open and close door
to determine the position of the
photoelectric sensor.
E11
Door neither opens
nor closes. Slack
rope switch has
triggered
Check ropes.
E91
Door neither opens
nor closes. Continu-
ous STOP command
detected
Check STOP button at J1. Stop
membrane key actuated.
F2
F3
F4
No response
Error occurred during self-testing.
Replace control.
F5
Reset has been
executed
Check mains environment with
regard to electrical disturbance
sources, increase distance of mo-
tor cable and / or signal lines to
mains cables, actuate start button
on control for normal operation.
F10
Door stops shortly
after start command
Fault in the control electronics.
Exchange control.
F19
Door responds only to
dead man's control
for closing
Closing edge testing has failed.
Check closing edge safety
device.
F20
Door responds only to
dead man's control
for closing
Testing of photoelectric sensor
has failed. Check photoelectric
sensor.
F21
Brief operational in-
terruption
Door movement exceeded time
value detected (90 sec). Check
door for ease of motion or block-
age. Check end positions.
F23
No response
Electronic door lock EDL100 is
not responding. Check wiring.
Locking bolt is jammed, check
locking bolt for ease of motion.
Do not apply oil or grease to door
locking.
F24
No response to start
command
No connection to the DES. Check