Rating plate
The rating plate is located at the side on the control housing. Ob-
serve the power supply specifications.
Made in Germany
W
N
X
X
X
X
X
X
X
X
/X
X
7
1
2
3
4
5
6
1 Control type
5 Max. motor power
2 Manufacturer and address
6 Protection type
3 Supply voltage
7 WN number
4 Amperage
Technical data
Height x width x depth
250 mm x 215 mm x 120 mm
Assembled vertically
Cable feed-throughs
6 x M20
2 x M16
2 x M20 V cutout
Supply voltage
3N~ 400 V
3~ 230 V
1N~ 230 V
Control voltage
24 V DC
Max. motor power
Max. 3.0 kW
Safety according to
EN 13849-1:
Input STOP A: Cat 2 / PL = C
Input STOP B: Cat. 2 / PL = C
Input STOP C: Cat. 2 / PL = C
Protection type
IP 54, optional IP 65
Operating temperature
-20 °C
+50 °C
Manufacturer
Novoferm tormatic GmbH
Eisenhüttenweg 6
D-44145 Dortmund
www.tormatic.de
4
Installation
DANGER
Hazardous voltage
The product runs on high voltage Before starting
with the installation,observe the following:
•
Have all work on electrical connections car-
ried out by a skilled electrician.
•
The power connection must be executed in
compliance with the mains voltage avail-
able.
Follow the instructions as well as the illustrations in the
"Connection diagrams" chapter.
1.
Tools required
For the assembly of the control, you require the following tools:
•
wooden folding rule or tape measure
•
cross-tip screwdriver Phillips; size 2
•
drilling machine
•
drill 6 mm
•
Torx screwdriver, size T20
•
slotted screwdriver for electricians
•
spirit level
•
marking pencil
2.
Opening the control cover
Open the housing cover by either loosening the two screws on
the left or right on the cover.
3.
Assembly of the control
Assemble the control as specified on the drilling drawing.
NOTICE
Selection of the place of installation
When selecting the place of installation, observe
the preconditions in compliance with the tech-
nical data.
4.
Terminal designation
J1
Start / pulse input (OPEN / STOP / CLOSE
J2
Photoelectric safety barrier 2- or 4-wire
J3
Safety edge OSE / 8K2 / DW
J4
Emergency stop, slack rope, locking
J7
Key switch / pull switch
J9
Digital limit switch - motor cable
J10
Connection of extended controls
J11
Connection of radio receiver
J12
Antenna
J13
Membrane keypad
X1
Power connection
X2
Power output L, N (500 W / 230 V)
X3
Protective earth contact
X5
Potential-free relay contact 1, door status relay
X6
Potential-free relay contact 2, door status relay
X7
Door drive
X8
24 V DC, max. 200 mA