3.8. Display Setup
Multi-Screen Sequence Display and Spot Monitoring may
be set up in this menu and adjustments of video distortion
or problems may be made.
CATEGORY
DEFAULT
VALUE
FUNCTION & OPERATION METHOD
MULTI-DISPLAY MODE
SEQUENCE MODE
NORMAL
•
Set whether to use the Sequence or Cameo function.
•
NORMAL : The displayed channels will be displayed briefly on
screen before changing to the next channel in the
sequence list.
•
CAMEO : The screen on the bottom right hand corner will display
the remaining channels in sequence mode during
4 & 9 multi-screen display. In the 13 multi-screen
display mode, the middle screen will act as the cameo
screen.
Turn the mouse wheel to change between NORMAL
⇔
CAMEO
MULTI-DISPLAY MODE
SEQUENCE DWELL TIME
10
•
The Sequencing feature allows a camera to be displayed briefly on
screen, before advancing to the next camera.
•
Set the sequence dwell time.
•
Input Range : 1~600 Seconds
Turn the mouse wheel or use the pop-up Key Panel to change
the dwell time.
FLICKER CANCEL
YES
•
Select this feature if the GUI becomes shaky when using
composite output
Turn the mouse wheel to select between YES
⇔
NO.
COLOR DIFFUSION
NTSC : 8
PAL : 18
•
Set to compensate/correct Color Diffusion when using composite
video output
•
Input Range : 0~32
Turn the mouse wheel for adjustment.
Adjust the level based on the status of the 3 color boxes.
VGA DE-INTERLACE
BOB
•
When viewing video in the progressive(VGA) scan mode, the
interlaced image is transformed to the progressive image. And if
there is no moving images, horizontal lines(Tearing) will appear
on the screen. Selecting “BOB” will make the tearing disappear
and if there is no moving images on screen, selecting “WEAVE”
will provide a clearer image.
Turn the mouse wheel to change between BOB
⇔
WEAVE.
SPOT OUT
SEQUENCE DWELL TIME
0
•
Set the channel sequence dwell time for the SPOT Monitor.
•
Input Range : 0~600 Seconds
Turn the mouse wheel or use the pop-up Key Panel to change
the dwell time.
SENSOR ACTIVATION
Disable
•
Set whether to use Spot output when sensor is triggered.
Click on the check box to enable/disable.