9
2-3
Electrical Connections
Ensure proper power availability to prevent motor failure or dangerous electrical overloading. Compare the
motor nameplate for required amperage.
Do not use electric pump if the 3-prong electrical plug is not whole.
Minimize the length of extension cords and be sure they are of adequate wire size, with ground connections.
Extension cord should be #10 AWG gauge.
WARNING: Electric motors may spark. Do not operate in an explosive atmosphere or in the
presence of conductive liquids. Use an air motor pump Instead.
2-4
Air Connections
Ensure that you have sufficient air flow (in cfm) to operate your pneumatic pump. If in doubt, compare the pump
manufacturer’s recommended air flow rating prior to pressurizing pump. Improper air flow may damage the pump
motor. For best results use air hoses larger than 3/4” I.D. diameter.
Use of a filter regulator lubricator (FRL) is highly recommended. (Pictured below.)
1. Adjust flow to one drop per 60 - 90 seconds
2. Fill half way with grade 46 hydraulic oil supplied