7)
The brightness (sun) sensor requires to disable the controls of the rain and wind
sensors for the outputs
M5
and
M6
by means of the “DIP-switch”
No.6
, which has to
be on
“OFF”
position. The brightness sensor can have two opposite functions;
To select the wished function, it is necessary to act on the “DIP- switch”
No.4
placed
on the electronic card programming it as follows:
8)
By programming the “DIP-switch”
No.5
, it is possible to modify the type of control.
When the “DIP-switch” is programmed on "AUTOMATIC" mode, radio control or
remote control operates on a step by step system basis (open, stop, close, stop,
etc.),while the control by manual push button works with the operating system step
by step with two contacts. When it is programmed on "MAN PRESENT" mode, only
the manual push-button is enabled. This choice of indirect safety excludes
consequently all commands coming from radio control and remote control.To vary
this function, set the following programming:
16
TF24R/44R
Tab.4
ON
OFF
OFF
ON
INSTALLATION AND USE INSTRUCTIONS
INSTALLATION -5
Function
Position of DIP-switch No.4
If the OPEN (+ light) threshold is exceeded
If the CLOSE (+ light) threshold is exceeded
Function
Position of DIP-switch No.5
Automatic
Man present
Tab.5
9)
By programming the "Dip-switch" No. 7 it is possible, only for a general actuators
command, to set the activation times of the relays that control the motors (this
function is necessary to increase the number of connectable actuators).
1 second delay between 2 consecutive command.
1 minute delay between 2 consecutive command.
Tab.6
Function
Position Dip-switch N.7
ON
OFF
10)
"Dip-Switch" No. 8 must be programmed when a thermostat is connected to the
control unit (in this case, the controller provides a hysteresis of 5 min. over the
general opening and closing controls).
Important note: if you want to activate dip-switch No. 5, it has to be in automatic
mode (OFF).Once it has been activated, the thermostat controls all the
outputs; in any case, you can still control them also manually (via remote
control or push-button). The thermostat regains control over the actuators
operated manually when it gives a new command contrary to what had been
previously given by the remote control (or push-button).