background image

# until the green lights flash fast. and then input    new PIN      #      new PIN      # , 

new PIN will be changed successfully with a long buzz. 

6.10 How to Delete User by Input User ID NO. 

#    Programming Password    #    42    input User ID No.    # 

6.11 How to Delete User by Input Card NO. 

#    Programming Password    #    43    input card No.    # 

6.12 How to Delete User by Input Access Password (PIN) 

#    Programming Password    #    44    (3-6 digits access password)    # 

6.13 How to Delete All Access Password (PIN) Users 

#    Programming Password    #    45    1111    # 

6.14 How to Change Open Time 

#    Programming Password    #    5    XX    # 

NOTE: XX can be 2-digit, and the max. is 99. If input 00, the signal output time is 

0.2 Second. 

6.15 How to Set Open Mode 

#    Programming Password    #    6    XX    # 

NOTE: XX can be 01(only card)/ 02(card or Access Password)/ 03(card+PIN) 

6.16 Reader Setting (For options) 

#    Programming Password    #    6    04    # 

NOTE: The machine can be used for reader(W26 output) 

6.17 Security Function Setting, Anti-dismantle Alarm Setting (For options) 

#    Programming Password    #    7    XX    # 

NOTE:  XX  can  be  01/  02(  Security  function  OFF/ON)  and  03/04(Anti-dismantle 

alarm  OFF/ON).  Security  Function  ON  means  System  would  be  locked  for  5 

Minutes  if  continue  to  read illegal  card  or  input  wrong Access  Password  for  10 

times. 

6.18 Backlight setting(For options) 

#    Programming Password    #    8    XX    # 

NOTE: XX can be 01/02 (Normal ON / Normal OFF) 

6.19 How to Reset Factory Default Setting 

#    Programming Password    #    8    99    # 

NOTE:

 

Except Programming Password. 

7. Reset to Factory Programming Password

123456

 

Step1: Power off the keypad and connect pin 2&3 of RST together. 

Step2: Power on the keypad and buzzer will give 3 long buzz with green light flashes 

fast. 

Summary of Contents for LM175P

Page 1: ...light Auto for options Relay Unlock output 5 Seconds W26 port Input for options Security mode OFF Open mode Card or Access Password Access Password include Private Access Password PIN and Common Acces...

Page 2: ...e gate door opener NOTE Below wiring diagram is a universal wiring diagram of the connection between the keypad and the opener You can refer to the user manual of the TOPENS gate opener for detailed w...

Page 3: ...without power on the board when using external power supply for TC175P In this situation you need an external 12 24VDC power source to make the keypad to work with the gate door opener 6 Programming...

Page 4: ...an be set up to 1000 sets You can input access password and then press to activate the keypad 6 4 How to Add User Card Programming Password 1 read card NOTE If add multi cards read cards continuously...

Page 5: ...nly card 02 card or Access Password 03 card PIN 6 16 Reader Setting For options Programming Password 6 04 NOTE The machine can be used for reader W26 output 6 17 Security Function Setting Anti dismant...

Page 6: ...you need to set one yourself first Otherwise the device can not work normally if you use password mode And please note that 123456 is not password It is factory default programming code Set password o...

Page 7: ...123456 5 then choose to enter time 0 99 seconds digitals and press to finish 5 Delete the learned card Press 123456 41 then read the card and press to finish The card was deleted successfully 6 Back t...