18
TF90-TRS
5.15
Disturbances - Disturbance Display and
Remedy
Disturbance
Possible Cause
Remedy
No operation of one of the
electrical consumers:
Fault in electrical wiring
Check plug connections
Battery empty
Charge Battery
Sweeping result unsatisfactory
Side brush(es) or main sweeping
rollers not lowered
Lower
Side brush(es) or main sweeping
rollers worn
Replace
Trajectory clogged by dirt
Check if roller trim panel is
impaired by jammed debris
Main broom (s) do not operate
Correctly fitted?
Brush rollers are jammed by dirt,
cords, strings or the like
Dismount brush rollers and clean
them
Check side brushes and remove
obstacles
Drive wheels obstructed
Jack up the Sweeping & Suction
Machine
check wheels and free running
In addition, the following applies
to TF90-TRS
Filter heavily polluted
Open the ventilation flap
Filter not correctly fitted
Clean filter
Leakage and subsequent
aspiration of false air in the filter
chamber mer
check for tight fit
check if false air is sucked in
Ator does not move freely
Check ventilator wheel and
remove any obstruction
2x green switch lights and 2x red
battery lights flashing
Brush drive motor overload
Inspect brushes and brush
bearings for binding etc