background image

iii 

 
2000010184 Revision D, 9/04 

 
 

 

CONTENTS 

 

 

1.0 

NOMENCLATURE 

         1 

1.1    Model OC-2200 Main Components 

 

 

 

 

 

 

 

 

 

2.0 

PERFORMANCE 

AND 

SPECIFICATIONS 

      1

 

 

3.0 

ASSEMBLY           3 

3.1 

Tools 

           3 

3.2 

Ophthalmic 

Chair 

Stand 

Position 

       3 

3.3 

Electrical 

Connections         3 

3.4 

Alternate 

Connections 

         3 

3.5 

Power 

Up 

          4 

 

4.0 

OPERATION 

          4 

4.1 

Elevation 

Control 

         4 

4.2 

Recline 

Control          4 

4.3 

Swivel 

Brake 

Operation 

        4 

4.4 

Armrest 

Retraction 

         4 

4.5 

Headrest 

Position 

         5 

4.6 

Footrest 

Retraction 

         5 

 

5.0 

ADJUSTMENTS 

          5 

5.1 

Headrest 

Locking 

Tension 

        5 

5.2 

Swivel 

Brake 

Adjustment 

        5 

5.3 

Armrest 

Adjustment 

         6 

5.4 

Changing Control Switch from Right Hand to Left Hand 

 

 

 

 

 

6.0 

 

 

MAINTENANCE 

          6

 

  

6.1 

Paint 

and 

Nonmetallic 

Parts 

        6 

  

6.2 

Upholstery 

          6

 

 

7.0 

 

TROUBLE 

SHOOTING 

         7 

Summary of Contents for OC-2200

Page 1: ...i...

Page 2: ...ient in a safe condition if a malfunction occurs After Operation Never disconnect any plugs by pulling on the cable Doing so may cause damage to the internal connections If the chair has been idle for...

Page 3: ...ctions 3 3 5 Power Up 4 4 0 OPERATION 4 4 1 Elevation Control 4 4 2 Recline Control 4 4 3 Swivel Brake Operation 4 4 4 Armrest Retraction 4 4 5 Headrest Position 5 4 6 Footrest Retraction 5 5 0 ADJUST...

Page 4: ...rest Height 3 5 89mm 1 5 38mm Full Recline Length 75 1905mm Mode of Operation Continuous Use Type of Protection Class 1 protection Against Electrical Shock Ingress of Water Protection Ordinary Protect...

Page 5: ...es F 23 to 54 Degrees C Relative Humidity Range 30 to 95 Atmospheric Pressure Range 10 1 to 15 4 psi 700 to 1060 hPa Acceptable Storage Time in operating environment 5 years in extreme environment 20...

Page 6: ...appropriate wall outlet or into the ophthalmic stand 2 Connect the chair control cable to the ophthalmic stand and check the vertical movement of the ophthalmic chair 3 4 Alternate Connections When th...

Page 7: ...t of the manual recline ophthalmic chair model OC 2200 is made by pressing the appropriate arrow button on the membrane switch located at the side of the back or with an optional footswitch The chair...

Page 8: ...ng tension Clockwise for more tension counter clockwise for less tension Adjust the clamp tension so that the clamp locking handle closes easily and the pivots at each end of the clamp are secure Repe...

Page 9: ...snap ring off which holds the release button into the membrane switch Remove the membrane switch from the back casting Next remove the switch blank from the opposite side of the back casting and inst...

Page 10: ...ounter clockwise and simultaneously pressing down easily replace the fuses Carefully remove the fuse and check for breaks in the filament or for any corrosion at the ends If in doubt test the fuses wi...

Reviews: