13
10.
In some cases, the bracket has failed at the weld shown in
Figure 15
. It is recommended
that all sprayers with roll control add weld to the existing bracket to prevent failure. Some
sprayers from 2005 and newer already have gussets added at the factory.
Figure 15: Roll Cylinder Mount Weld Locations
11.
Install the 6MB-4MOR (F12) fittings into the cylinder.
12.
Install the 4MOR-4FORX90 (F14) fitting onto the cylinder fitting at the cap end of the
cylinder.
Figure 16: Roll Cylinder Installed with Hoses
Summary of Contents for NORAC UC4.5
Page 1: ...Active Roll ControlTM Option Installation Manual...
Page 5: ...2 2 Kit Parts 2 1 Kit Overview Figure 1 Roll Control Parts...
Page 6: ...3 2 2 Hydraulic Plumbing Figure 2 Roll Control Hydraulic Plumbing...
Page 11: ...8 Figure 7 Center Mark Location Centerline Mark 4 100mm...
Page 21: ...18 8 Cable Drawings 8 1 ITEM C07 43220 0 5 CABLE UC5 NETWORK 14 AWG 0 5M...
Page 22: ...19 8 2 ITEM C70 44658 46D CABLE UC4 VALVE DT ROLL WITH PIGTAIL...