7
4.
Mount the brackets (B09) as shown in
Figure 5
. Install two (2) cable ties per bracket.
Figure 5: Bracket Mounting (Looking from the Rear)
5.
Install the base end of the position sensor with the cable facing the center of the sprayer in
the lowest hole of the bracket possible without making contact with the boom frame. Use
the mounting hardware as shown in
Figure 6
.
Figure 6: Mounting Hardware
6.
Install the linear sensor mounting bolt in the hole of the upper bracket that closest aligns
the end of the sleeve with the center of travel mark (black mark) on the sensor (
Figure 7
).
If the mark is missing, the distance from the end of the sleeve to the top of the base should
be 4” (100mm). The collar (
Figure 6
) clamps the sensor and prevents the rubber
grommet from sitting on the bolt threads. Tighten the mounting hardware.
Collar
Bolt
Nut
Nut
Summary of Contents for NORAC UC4.5
Page 1: ...Active Roll ControlTM Option Installation Manual...
Page 5: ...2 2 Kit Parts 2 1 Kit Overview Figure 1 Roll Control Parts...
Page 6: ...3 2 2 Hydraulic Plumbing Figure 2 Roll Control Hydraulic Plumbing...
Page 11: ...8 Figure 7 Center Mark Location Centerline Mark 4 100mm...
Page 21: ...18 8 Cable Drawings 8 1 ITEM C07 43220 0 5 CABLE UC5 NETWORK 14 AWG 0 5M...
Page 22: ...19 8 2 ITEM C70 44658 46D CABLE UC4 VALVE DT ROLL WITH PIGTAIL...