Setting Raw Data & Position Update Rates to 50 Hz
P/N 7010-0935
4-13
Ok – closes the dialog box.
Setting Raw Data & Position
Update Rates to 50 Hz
This procedure sets the receiver to output measurement data and
position information at 50 Hz.
1. In PC-CDU, click
Tools
Receiver options
.
2. Make sure that the
Position update rate (Hz)
and
Raw data
update rate (Hz)
options display 50 in the Current column, and
then click
Exit
.
3. Click
Configuration
Receiver
.
4. Click the
Advanced
tab, and then the
Raw Data Management
tab. Set the following parameters, and then click
Apply
:
• Raw Measurement Update Rate, Update Rate – set to 20 ms.
• Position Update Rage, Update Rate – set to 20 ms.
5. Click
Refresh
, and examine the values in the Current Update
Rate fields. They should display 20.
6. Once verified, click
OK
.
When requesting any data recording or output with a period—that is,
a recording or output not directly supported by the current state of the
receiver—PC-CDU will launch the Output Period Setup Wizard. This
wizard performs the same steps described above. For details on the
wizard, see
PC-CDU Reference Manual
.
CAUTION
Always initialize the file system on the installed CF
card before the first use. It is recommended to
reinitialize the receiver file system on a regular
basis.