3 STANDARD MEASUREMENT MODE
3.2.5 Distance Measurement (Single/N-times Measurement)
When presetting the number of times, the instrument measures the distance as the setting times and
the average distance will be displayed.
When presetting the number of times as 1 or 0, it does not display the average distance, because of
single measurement. It has been set at single measurement at factory.
1)Setting the number of times
Refer to Chapter 5 “PARAMETERS SETTING MODE” .
2)Measuring Method
Confirm the angle measurement mode.
1
Collimate the center of the prism.
2
Select the measurement mode by pressing the
[
]
key.
Example:
Horizontal distance / Relative elevation mode
N-times measurement starts.
The average value is displayed following with
buzzer sound.
*1)The following characters will be shown on the 4th line right hand of the display to represent measurement
mode.
R=Continuous (Repeat); S=Single; N=N-times
*1)