43
2 PREPARATION FOR MEASUREMENT
2.5 Vertical and Horizontal Angle Tilt Correction
When the tilt sensors are activated, automatic correction of vertical and horizontal angle for
mislevelment is displayed.
To ensure a precise angle measurement, tilt sensors must be turned on. The display can also be used
to fine level the instrument. If the (TILT OVER) display appears the instrument is out of automatic
compensation range and must be leveled manually.
•
GTS-750/GPT-7500 compensates both the vertical angle and the horizontal angle readings due to
inclination of the standing axis in the X and Y directions.
•
For more information about dual axis compensation, see Chapter 18 “APPENDIX” .
•
The display of Vertical or Horizontal angle is unstable when instrument is on an unstable stage or a
windy day. You can turn off the auto tilt correction function of V/H angle in this case. To set TILT
correction mode ON/OFF, refer to section 2.5.1 “Setting Tilt Correction by Soft Key”or Chapter 5
“PARAMETERS SETTING MODE”
Inclination of the standing
axis in the X direction
Zenith
Standing axis
Zenith
Trunnion axis
Horizontal
Inclination of the standing
axis in the Y direction
Standing axis
When the instrument is out of compensation. (TILT OVER)
Standing Axis in the X direction
out of range
Standing Axis in the Y direction
out of range
Standing Axis in the X and Y
directions out of range
Summary of Contents for GPT-7500 Series