6-3
6 SPECIAL MODE (Menu Mode)
2) Without prism height input
Horizontal distance (HD) between the instrument
and prism will be shown.
8
Collimate target K.
Vertical distance (VD) will be shown. *2),3)
Collimate K
*1)
Refer to Section 2.4 “How to Enter Alphanumeric Characters”.
*2) To return to procedure
5
, press the
{F2}
(R.HT) key.
To return to procedure
6
, press the
{F3}
(HD) key.
*3) To return to PROGRAMS Menu, press the
{ESC}
key.
Operating procedure
Operation
Display
1
After pressing the
{MENU}
key, press the
{F4}
(P
↓
) key to get the menu on page 2.
{MENU}
{F4}
2
Press the
{F2}
key.
{F2}
3
Press the
{F1}
(REM) key.
{F1}
4
Press the
{F2}
key.
{F2}
5
Collimate prism.
Collimate P
6
Press the
{F1}
(MEAS) key.
Measuring starts.
{F1}
Horizontal distance (HD) between the instrument
and prism will be shown.
REM-1
<STEP-2>
HD* 123.456 m
>Measuring...
REM-1
VD: 1.500 m
––– R.HT HD –––
REM-1
VD: 10.456 m
––– R.HT HD –––
MENU 2/
4
F1:MEMORY MGR.
F2:PROGRAMS
F3:GRID FACTOR P
↓
PROGRAMS 1/2
F1:REM
F2:MLM
F3:Z COORD. P
↓
REM
F1:INPUT R.HT
F2:NO R.HT
REM-2
<STEP-1>
HD: m
MEAS ––– NP/P –––
REM-2
<STEP-1>
HD* [n] << m
>Measuring...
REM-2
<STEP-1>
HD* 123.456 m
>Measuring...