8-15
8 LAYOUT
5
Enter instrument height in the same way.
Enter
INS.HT
{F4}
6
Enter the known point A number. *3)
{F1}
Enter PT#
{F4}
7
Enter reflector height.
Enter R.HT
{F4}
8
Collimate the known point A, and press the
{F1}
(ANG) or
{F2}
(DIST) key.
Example:
{F2}
(DIST)
Distance measuring starts.
Known point B entering display will be shown.
Collimate A
{F2}
9
Same as procedure
6
to
8
proceed to the known
point B.
When two points have been measured by the
{F2}
(DIST) key, the RESIDUAL ERROR will be
calculated. *4)
10
Select GRID FACTOR for calculation of
RESIDUAL ERROR by pressing
{F1}
or
{F2}
key. *5)
Example:
{F1}
{F1}
11
Press the
{F1}
(NEXT) key to measure other
points.
Maximum seven points can be measured.
{F1}
12
Same as procedure
6
to
8
proceed to the known
point C.
NO01#
PT#:
INPUT LIST NEZ ENTER
REFLECTOR HEIGHT
INPUT
R.HT = 0.000 m
--- --- [CLR] [ENT]
REFLECTOR HEIGHT
INPUT
R.HT : 1.235 m
ANG DIST NP/P ---
HR: 123°40'20"
HD*[n] < m
VD: m
> Measuring...
< complete >
NO02#
PT#:
INPUT LIST NEZ ENTER
SELECT GRID FACTOR
F1:USE LAST DATA
F2:CALC MEAS.DATA
RESIDUAL ERROR
dHD= 0.015 m
dZ = 0.005 m
NEXT ––– G.F. CALC
NO03#
PT#:
INPUT LIST NEZ ENTER
HR: 123°40'20"
HD*[n] < m
VD: m
> Measuring...
< complete >
HR: 123°40'20"
HD: 123.456 m
VD: 1.234 m
NEXT ––– ––– CALC