DEFROST ICON
Led on:
defrost in progress
Led blinking:
defrost activation delay or dripping in progress
Led blinking at high frequency:
alarm memorized
FAN ICON
Led on:
room fans activated
Flashing LED
: ventilator activation delay
COMPRESSOR ICON
Led on:
compressor activated
Led blinking:
compressor activation delay
TEMPERATURE SETPOINT SETTING/VARIATION
Press and release the key
on/sby/enter
: the current setpoint blinks on the display for
5 seconds.
After 5 seconds, the displays shows the room temperature again
While the display is blinking, use the
up
and
down
keys to increase or decrease the
temperature setpoint
Press the
on/sby/enter
button again to confirm the new set point
SMART FUNCTIONS – Quick-access functions
Forced manual defrost
Push the
up
button, hold
down
for more than 3 seconds to access the manual defrost
functions.
Change in relative hu2°C/+10°C and -22°C/+5°C
Push the
down
button, hold down for more than 3 seconds to modify the percentage
of relative humidity in the chamber.
The temporary flashing confirmation label [
F_C
] corresponds to a too low relative
humidity (fans in parallel with the compressor).
The flashing temporary confirmation label [
F_ _
] corresponds to a too high relative
humidity (fans independent).
The relative humidity that blinks on the temporary label [
FtE
] is programmed by the
manufacturer.
Change in relative humidity +14°C/+16°C
Push the
down
button and hold down for more than 3 seconds: the display visualises
the current humidity setpoint for 5 seconds in a flashing modality.
Once that time has elapsed the display returns to the indication of the temperature in
the cell.
During the flashing mode on the display use the
buttons to increase or
decrease the humidity setpoint desired.
Push the
on/sby/enter
button to confirm the new setpoint: the acquisition of the new
value is signalled by an acoustic emission of 3 short consecutive beeps.
After 2 seconds the display returns to the indication of the temperature in the cell.