Val valid
N.O.Normally open
N.C. Normally closed
“Pt” Port
InpPt input port
Alm Inp Alarm Input
EmStpInp Emergency stop input
XAxs0X axis zero
ExtStart External start
ExtPause External Pause
IcSp Inp Increase speed input
RdSp Inp Reduce speed input
Man XPos Manual X positive direction
Man XNeg Manual X negative direction
Through setting the parameters, determine the specific definition of the external
input ports. Through pressing the ←, →, ↑, ↓ cursor keys, move the cursor. Through
pressing the PgUp, PgDn keys, turn the page. Through the Cfm(Confirm) key on the
controller panel, switch Proh(Prohibited) and Vld (Valid), or N.O.(Normally open)
and N.C.(Normally closed). Through the number keys 0-9 on the controller panel,
modify the parameter of the Pt(Port, short for InpPt(Input port)).
Proh(Prohibited):
Proh(Prohibited):
Proh(Prohibited):
Proh(Prohibited):
This function is not used.
Vld
Vld
Vld
Vld (Valid):
(Valid):
(Valid):
(Valid):
This function is valid.
N.O.(Normally
N.O.(Normally
N.O.(Normally
N.O.(Normally open):
open):
open):
open):
The selected switch status corresponding to the input port is
normally open switch.
N.C.(Normally
N.C.(Normally
N.C.(Normally
N.C.(Normally closed):
closed):
closed):
closed):
The selected switch status corresponding to the input port is
normally closed switch.
Pt
Pt
Pt
Pt 0:
0:
0:
0: Port
Port
Port
Port 0.
0.
0.
0.
Corresponding to the input port, the following number ‘0’ indicates that
the external input line is No. 0 line. Because No. 0 line does not exist, that is the input
port is not set. When need to set, No. 1-16 line can be selected to fill the setting.