Mobile service stations
EN
13
Place a new dust bag inside the bin and connect the flange to the suction union pipe. Verify that there are no signs of
damage or lacerations on the filtering fabric.
Place the head on the dust bin verifying that it is correctly oriented. Fix the head with the two metal hooks.
Connect the compressed air supply to the head of the suction cleaner using the quick fittings.
Removing dust residuals
At the end of each working day remove the dust accumulated on the flat surface of the suction cleaner (rear top, head,
etc.). If dust residuals are present, make sure that the metal pliers of the suction cleaner are connected to the grounding
system of the plant and carefully remove the residuals to avoid creating potentially explosive atmospheres.
SPECIAL MAINTENANCE MANUAL
In the event of defects or breakages, contact the dealer for replacement by qualified personnel or personnel authorized
by JBDC.
Before accessing the pre-filter, stop the suction unit.
JBDC shall not be held responsible for damage or malfunctioning caused by repair work, replacement and uninstallation
performed by unauthorized persons. You are advised to refer to internal regulations or requirements for safe conduct in
the presence of potentially explosive atmospheres or dust deposits.
Special maintenance regards:
- Filtering element: replace it if damaged or clogged following the procedure outlined below.
Wear a dust protection mask.
Disconnect the supply from the suction cleaner on the head.
Release the head loosening the metal hooks.
Rest the head on the floor and loosen the locking nut.
Loosen the metal wing nut and release the filter grounding cable.
Remove the locking nut and carefully extract the filter.
Place the filter in a bag and dispose of it accordingly.
Place the new filter on the frame and fit the locking nut making sure that it has been correctly tightened.
Fix the filter grounding cable to the head by tightening the wing nut.(see picture 7) Assemble the head on the suction
cleaner fixing it in place with the metal hooks, then reassemble the compressed air supply.
- Compressed air supply pipes of the suction cleaner: check their integrity and sealing every 6 months.
- Replacement of the suction cleaner parts: wheels, bin, head, metal pliers, suction sleeve, etc. (check their integrity
every 6 months)
- Replacement or reparation of frame damages (check every six months)
To avoid problems or failures, it is advisable to have the machine and the parts listed inspected every 6 months to make