Manual of instructions TT-188
9/37
1 Temperature Controller MP-888
2 ON/OFF-Switch unit (green)
3 ON/OFF-Switch heating (green)
Water: Switchable in stages 3 kW + 6 kW = 9 kW
Oil:
3 kW (OR-circuit)
4 ON/OFF-Switch horn (green)
5 Temperature monitoring internal left (red)
The maximum temperature of the unit is exceeded. The unit switches off.
Control lamp Temperature deviation control right (red)
Difference between desired and actual temperature is too big. Unit continues to run.
6 Control lamp thermal relay pump (red)
Thermal relay of the pump motor has responded, unit switches off.
7 Mould drainage (green)
- Cooling the unit below 60°C
- Switch the unit off by the green ON/OFF-Switch
- Changeover switch for pump operation mode to position
„Vacuum“
- Press the green button approx 5 sec.
8 Change-over switch for pump operation mode (red)
Pressure
for pressure operation (normal operation)
Vacuum
for leakstopper operation and mould drainage
9 Level control lamp pre-warning left (yellow)
horn
Unit continues to run, level has to be corrected
Level control lamp right (yellow)
horn
unit switches off
10 Flow control (red)
Alarm sounds by large changes.
11 Main switch
Emergency stop
12 Name plate with following details:
13 Switch cabinet
– safety device
14 Coverage
– safety device
Summary of Contents for TT-188
Page 8: ...Manual of instructions TT 188 8 37 2 Overview temperature control unit 2 1 Front view ...
Page 13: ...Manual of instructions TT 188 13 37 4 EU Declaration of conformity ...
Page 34: ...Manual of instructions TT 188 34 37 ...
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ......
Page 44: ......
Page 45: ......