4
1.3.
Safe distances:
Safe distance A
Sides and rear panels require a minimum distance of 10 cm to inflammable
materials
Safe distance B
The national and local rules and regulations
are to observe
Safe distance C+D
The entire turning range requires
a minimum distance of 50 cm
Safe distance E
The entire turning range requires
a minimum distance of 80cm
Safe distance F
The minimum distance to the ceiling
is 50 cm
1.4.
Spark protection plate:
Flammable floor coverings in front of the stove must be protected by a non-
flammable covering. Plates made of stone, ceramic, sheet metal or Securit
glass are suitable for this. Flammable floors in front of the stove (carpet,
parquet, plastic) must be covered over. Building regulations, state building
ordinances and fire protection laws differ from country to country. Enquire to
the authority or chimney sweep responsible for the acceptance before
installing.
CAUTION
CAUTION
Fire prevention laws stipulate minimum or safe distances for
inflammable materials (wood panels, panelling, fabrics, etc.).
These are
given by the table below: