5
1.5.
Approvals and appliance rating plate:
The appliance rating plate provides information about the various approvals
carried by the T-LINE. The plate is attached at the bottom on the inner side of
the stove door.
In the case of technical enquiries regarding the stove or questions about the
warranty, the stove number on the rating plate must always be given in
order to be able to identify the stove.
Triple point values according to DIN EN 13384:
Flue gas mass flow
g/s
7.0
Flue gas temperature
°C
312
Necessary pressure difference
Pa
11
1.6. Fitting the flue gas conncetion and combustion air supply for ambient air
independent operation
The flue gas evacuation system and combustion air supply must be
designed pursuant to the FC61x classification in the case of balanced flue
operation and evidence to this effect must be provided pursuant to DIN EN
13384-1:2008-08 and DIN EN 13384-2:2009-07.
Tonwerk Lausen AG recommends and supplies the Lindab connecting
system for the combustion air supply. The required elements must be
specified when ordering.
The joints of individual connecting elements of the combustion air supply
must be tightly sealed.
Flue pipe connections at the stove and wall must be sealed.
By room air independent operation with automatic air ventilation for the
housing space, it’s only allowed a chimney multi configuration when the
installation is in the same housing unit.