background image

 

12 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

 

Note 

 

 

 

It must be ensured that the heat storage blocks are installed flush with 
the edge of the housing at the sides and the rear and thatno great gap 
between the storage stones is created. 

 

Note 

 

 

 

It`s  important  that  the  flue  pipe  connection  and  the  cleaning  opening 
must  be    tightly.  This  also  applies  the  transitions  between  nozzles  to 
chimney and flue pipe to ceiling connection or wall connection. 

10.  Slide the flue gas baffle  

plate in from above 

11.  Insert the front storage plate and refit the 

start-up flap at the top 

12.  Test the function of the start-up flap 

13.  Refit the storage cover and ensure that the seal is positioned correctly 

14.  Refit and screw down the top sheet metal screen 

Summary of Contents for T-Art eco2

Page 1: ...1 Installation Instruction Tonwerk storage stove...

Page 2: ...t operation 7 2 Unpacking the T LINE 8 3 Assembly steps 9 3 1 Step 1 9 3 2 Installing the stove housing 9 3 3 Step 2 Flue gas and supply air connections 9 3 3 1 Connecting the combustion air supply fo...

Page 3: ...ing capacity of the substructure is sufficient to bear the weight of the stove Strong oscillations of flexible substructures timber floors can lead to defects in the stove and make the installation of...

Page 4: ...tion plate Flammable floor coverings in front of the stove must be protected by a non flammable covering Plates made of stone ceramic sheet metal or Securit glass are suitable for this Flammable floor...

Page 5: ...ply for ambient air independent operation The flue gas evacuation system and combustion air supply must be designed pursuant to the FC61x classification in the case of balanced flue operation and evid...

Page 6: ...eal or high temperature silicone Fastening to TL elbow support with Lindab hose clamp TKS R 165 The connection must be sealed with tape e g insulated aluminium hose Lindab THCOMB 125 mm Formation of c...

Page 7: ...suitable for room sealed operation and are hence not permitted Flue pipe d 150 Commercially available flue pipe Wall thickness 2 mm with sealed cleaning aperture Seal chimney connection with rope seal...

Page 8: ...endangered Each appliance is assembled and checked for completeness and damage during the works acceptance However if you should find defects that are attributable to transport damage contact Tonwerk...

Page 9: ...ng the combustion air supply for room sealed operation The supply air can be tightly connected vertically downwards or horizontally to the rear using commercially available flexible aluminium pipe wit...

Page 10: ...of the dimensioning It is recommended to calculate the dimension of the supply air pipe using the chimney calculation program Note The free cross section of 125 mm may not be reduced In particular wh...

Page 11: ...stone and push it right to the back The stone must be in a horizontal position 6 Clean the surface of the bottom storage stone 7 Slide the top lateral storage stone in until it is positioned at the r...

Page 12: ...the cleaning opening must be tightly This also applies the transitions between nozzles to chimney and flue pipe to ceiling connection or wall connection 10 Slide the flue gas baffle plate in from abov...

Page 13: ...he pane of glass the side plate should be approx 2mm back from the pane of glass Screw on the top side plate B and after aligning it at the bottom secure the centring pin with the lock nut 3 The door...

Page 14: ...14 4 Unscrew the start up flap control knob A mount the rear panel B and screw down at the top and bottom Screw the control knob back on 5 Place the cover stones back on top B A...

Page 15: ...ves beyond dead centre to the stop and locks the door properly Note 1 Before connecting the supply air check that the air flap closes by pressing the reset button audible closing noise 2 Check whether...

Page 16: ...immediately for safety reasons 4 Turntable option 4 1 Placing the turntable In the case of a stove with a turntable this must be placed on the floor first 1 The turntable must be always placed in the...

Page 17: ...ing in the desired position Assembly screw in to the stop then turn back out secure with lock nut 1 Stop for 45 angle of rotation Total angle of rotation 90 grad 2 Stop for 60 angle of rotation Total...

Page 18: ...Complete the warranty certificate in the presence of the customer and return it to us Please contact our Customer Service Dept on 41 0 61 935 17 10 if you should have any questions Subject to change w...

Reviews: