Bit3: Overload or not
Bit4: Unbalanced or not
Query Example: If you enter the command: :STAT:SLAV?, the returned content is: 1 has the following
meaning:
Bit0: 1 The slave has been turned on
Bit1: 0 Not running
Bit2: 0 Not overheat
Bit3: 0 Not overload
Bit4: 0 Not unbalanced
:STAT:WORK
Function: Query the current working state of the slave.
Command Format:
Query Format: :STAT:WORK?
Returned Info:
Data type: String
Data Range: running, preparing
Meaning:
Running: The instrument is outputting current
Preparing: The instrument is in the state of preparing
Query Example: If you enter the command: :STAT:WORK?, the returned content is: running, indicating
the instrument is outputting current.
4.2.4 System Sub-System Command
System Sub-System Command is used to remotely set the system of the instrument.
:SYST:BAUD
Function: Set or query the baud rate
Command Format:
Set Format: :SYST:BAUD <data>
Query Format: :SYST:BAUD?
Data:
Data Type: Enumeration, 4 byte
Data Range
:
9600,19200,38400,115200
Data Accuracy: -
Data Unit: -
Set Example: To set the baud rate to 9600, enter the command: :SYST:BAUD 9600
Query Example: If you enter the command: :SYST:BAUD?, the returned content is: 9600, indicating the
current baud rate is 9600.
:SYST:BEEP
Function: Set or query the beep is on or off
Command Format:
Set Format: :SYST:BEEP <data>