the float switch and splice to the TV leads. The float switch must be of the normally closed (NC)
type, i.e. when the switch is hanging down the contacts are closed. Remove the wire nut from the
leads on the wire marked “Tank Level” and connect to the float switch wires. Wires can be con-
nected either way, there is no polarity.
4.3.2 EXTERNAL PRESSURE TANK SWITCH WIRING
If the pressure tank switch option is ordered, the tank switch will be mounted at the tank and the wire
leads for “pre-treat are to be wired into one set of contacts in the switch. The product water check
valve will also be installed. You need only connect the product water fitting to your distribution
system and the pressure tank. If you are providing the pressure tank, check valve and tank switch,
the switch must be a normally closed (NC) type. Remove the wire nut from the leads on the wire
marked “tank level” and connect to one set of contacts in the tank switch.
4.3.3 PRE-TREAT LOCKOUT SWITCH WIRING
The pre-treat lockout switch must be wired through the normally closed set of contacts in the pre-
treatment system(s). If there is more than one equipment that must control the TV system on/off,
such as a GAC auto back wash filter and, say, a multi-media auto back wash filter, the switches in
the auto valves would be wired through the Common and NC terminals, in series, to the RO system
controller wires marked “pre-treat”. Since these contact inputs to the controller are dry contacts
there is no wire preference or polarity for making the connections.
5.0 STARTUP, FLUSH AND PERFORMANCE VERIFICATION
Although TV-Series systems are fully tested at the factory prior to shipping, it is strongly recom-
mended to flush and verify your system’s performance on-site, particularly if the unit was not in-
stalled soon after delivery.
NOTE
FOR 3 PHASE POWER DO NOT ATTEMPT TO RUN THE SYSTEM BEFORE THE PUMP
ROTATION HAS BEEN VERIFIED AS INSTRUCTED BELOW.
5.1 PUMP ROTATION DIRECTION (3-Phase models only)
Every TV-Series is thoroughly tested at the factory prior to shipment with factory 3-phase power
connected for proper pump motor rotation. Your 3-phase power connection must also be configured
for proper pump rotation. With the water supply on, turn the power switch on, then the controller
power on momentarily, and check the direction of rotation of the pump. There is a direction of
rotation arrow on the body of the pump. Observe rotation of the motor at the top end. If rotation is in
the wrong direction, reverse any two of the 3-phase power leads at your fused disconnect.
5.2 INITIAL STARTUP AND FLUSHING
New membranes have a preservative on them that should be flushed before use. Although the
system was run at the factory, additional flushing is recommended. Run the product line to a drain
and run the system as follows until the product TDS has stabilized.
Fully close the RECIRC valve by turning the knob full CW.
Fully open the brine control valve by turning the knob full CCW.
Turn on the water supply to the unit and check for leaks up to the solenoid valve.
Turn the OFF-POWER-ON power to ON.
15
Summary of Contents for TV-6000
Page 2: ...TOMAR TV 6000 SYSTEM ...
Page 7: ...Figure 1 Typical System Configuration TV 12K shown 5 ...
Page 13: ...Figure 2 System Plumbing Diagram 11 ...
Page 14: ...Figure 3 System Electrical Schematic Diagram ...
Page 20: ...Figure 4 PVC Vessel Membrane Assembly 18 ...
Page 21: ...Figure 5 Stainless Steel Vessel Membrane Assembly 19 ...
Page 28: ...25 NOTES ...
Page 31: ......