EN - 21
Connection with a flexible steel hose
If the hob is connected according to the class 1 specifications, only flexible metal hose can be used which meet the valid
national regulations. Gas feeding connector must be G ½” threaded coupling. Use only pipes and fittings that
meet the requirements of the valid standards. Maximum admissible length of the flexible hose is 2000 mm. Make sure the
connection is not touching any mobile elements which could damage the hose.
Connection with a stable pipework
The hob comes with a G ½” threaded coupling. The connection to gas supply must be done in a manner that excludes stresses
in any point of the pipework or parts of the appliance. Make sure you do not exceed the torque when making the connection
(maximum torque is 20 Nm). Otherwise, the connection may be faulty or leaks may occur.
The gas hose should not touch metal elements of the hob back shield.
Important!
Each time you replace a reducer, carry out technical inspection of the hob that covers gas valves and proper
operation of the flame failure cut-off device.
Caution!
On completion of the hob installation, the tightness of all connections should be checked, e.g. applying water
with soap. Do not use fire to check tightness.
ELECTRICAL CONNECTION
ADAPTING THE HOB TO ANOTHER TYPE OF GAS
This operation may only be carried out by an appropriately authorised fitter.
If the gas the hob is to be supplied with differs from the gas provided for the hob by the manufacturer, that is G25/ 25.3 / 25 mbar,
burner nozzles must be exchanged and the flame needs to be adjusted.
In order to adapt the hob to burn a different type of gas, you should:
• exchange the nozzles (see the gas tables below);
• adjust the “economical” flame.
Caution!
The hobs provided by the manufacturer have burners which are factory-adapted to use the gas specified on their
rating labels.
Gas table
G25/ 25.3-25 mbar*
G20/20 mbar
G30/30 mbar
SABAF burners
Injector
diameter
Injector mark
Injector
diameter
Injector mark
Injector
diameter
Injector mark
1
0.72 mm
72
0.72 mm
72
0.50 mm
50
1 Simmer burner 0.95 kW
2
0.97 mm
97
0.97 mm
97
0.65 mm
65
2 Semi-rapid burners 1.70 kW
3
1.15 mm
115
1.15 mm
115
0.85 mm
85
1 Rapid burner 2.90 kW
Burner flame
Re-arming from liquid gas to natural gas
Re-arming from natural gas to liquid gas
Full
1. Exchange a burner nozzle for the appropriate type
according to the gas table.
1. Exchange a burner nozzle for the appropriate type
according to the gas table.
Economical
2. Unscrew an adjusting bolt slightly and adjust the flame size. 2. Screw in an adjusting bolt slightly and check the flame size.
In order to perfom adjusting operations, take off the knobs.
•
Check that the voltage in your home corresponds with the voltage printed on the bottom of the appliance
.
• The earthing of the appliance is compulsory by law.
•
Attention:
the connection point must always be accessible.