37
FULLY AUTOMATED WATER TREATMENT PLANT FOR YACHTS AND HOUSEBOATS
aquonic | User Manual
All hose connections must be secured twice with opposite hose clamps.
The fresh water lines will be interlocked and with a lock ring secured. The
hose should be wetted before connecting (dipping into a cup filled with a
mixture of water and dishwashing agent, rinsing agent works too). Push
the hose up against the inlet and insert the clip. For disconnecting, remove
the blue clip and push the inlet towards the adapter and pull out the hose.
The electrical connection must be done with a protected live cable directly
connected to the plant’s socket. The cable markings are ALWAYS as follows
(applies to the whole plant):
Cabel number 1
red
Plus
+
Cabel number 2
blue
/black Minus -
MAKING THE CONNECTIONS
Cabel number of
remote control switch:
cabel no.
contact switch
1
13 and 23 (Bridge)
2
X2
3
14
4
24
5
X1
UVC-reactor
Fresh water outlet
Tap or waste
water outlet
Diaphragm
Flushing valve
Pressure pump
Summary of Contents for aquonic