Nominal 12VDC Output
5. Allow the engine to run for several seconds. Wait for the output light to light up.
6. Then, move the combination switch slowly to its run position.
NOTE:
Moving the Combination Switch too fast could stall the Engine.
IMPORTANT:
Allow the Engine to run at no load for five minutes with no load after each start-up so that the
Engine can stabilize.
OPERATING INSTRUCTIONS
12
Break-in period:
a. Breaking-in the Engine will help to ensure proper equipment and Engine operation.
b. The break-in period will last about 30 hours of use. DO NOT exceed 75% of the Generator’s running
wattage during this period.
• Change the engine oil after this period.
Under normal operating conditions subsequent maintenance follows the schedule explained in the
MAINTENANCE
section.
1. Do not use any 230VAC outlet while using the 12VDC outlet.
2. Move the Economy (ECO) Switch to the OFF position.
3. Only use the 12VDC receptacle to charge a 12 volt lead-acid type battery using an appropriate charge
controller. (Battery and controller not included.) The 12VDC output is not regulated.
4. Do not connect any device to the 12VDC terminal that draws more than 8.3 amps.
5. If this 12VDC circuit protection is tripped, reduce the load, and press the Reset Button next to the outlet.
5