16 (20)
2.4 Settings:
There are a number of settings that can be changed for the product.
Setting
Values
Standard
Delayed OFF
1–4 hours
2 hours
Water OFF after a power outage OFF, Reset as before power outage
OFF
At pressure drop
Water ON or OFF
Water ON
Volume limit
1L–100,000L
500L
Language
Swedish, Norwegian, Danish, Finnish, English
Swedish
Advanced setting
Connected units
Handle wireless units
- RSSI
Indicates the signal strength of the most recent radio communication.
- Temperature
Shows current temperature (Only applies to water sensors)
- Battery level
Shows current battery voltage and whether this is OK.
- Change unit name
Change the name of an already installed unit
-
- Remove unit
Removes an installed unit
-
Search for new unit
Install wireless units
-
Pressure drop measurement
Automatic pressure drop measurement
ON
Volume measurement
Requires a water meter with digi. output port
OFF
- Volume per pulse
Set depending on water meter
1L/PULSE
- Volume limit
At which water volume should turn OFF
500L
Temperature limit
At which temperature should the water be turned off.
OFF, 1, 2, 3, 4, 5 degrees
3 degrees
External alarm
Settings for external control
ON/OFF
2.4.1. Connected units
In order to handle the function of already connected units, you can use the following menu selection.
First select which unit you wish to manage “Select unit” and press OK, then move down to the
desired function.
“RSSI”, Indicates the signal strength of the most recent radio communication.
“TEMPERATURE”, Shows current temperature, Only applies to water sensors.
“BATTERY LEVEL”, Shows current battery voltage and whether this is OK.
“Change name?”, easily change the name of a unit by moving down using the right/left arrows and
confirm by pressing OK.
“Remove?”, used to remove connected units.
Note!
If a unit is no longer in use, it needs to be permanently removed from the system, if not, the
system will automatically expect the “I’m alive” signal from the unit every 24 hours and the central
unit will trigger the alarm with a “beep” signal every three minutes after three days, “LOST CONTACT”,
“DISHWASHER”.
2.4.2. Search for new device
Upon installation of an additional remote unit or water sensor to expand the system, you can use