background image

16 (20)

2.4  Settings:

There are a number of settings that can be changed for the product.

Setting 

Values 

 Standard

Delayed OFF 

1–4 hours 

 

2 hours

Water OFF after a power outage  OFF, Reset as before power outage 

 

OFF 

At pressure drop 

Water ON or OFF 

 

Water ON

Volume limit 

1L–100,000L 

 

500L

Language 

Swedish, Norwegian, Danish, Finnish, English 

Swedish

Advanced setting

  

Connected units 

Handle wireless units

- RSSI 

Indicates the signal strength of the most recent radio communication.

- Temperature 

Shows current temperature (Only applies to water sensors)

- Battery level 

Shows current battery voltage and whether this is OK.

- Change unit name 

Change the name of an already installed unit  

-

- Remove unit 

Removes an installed unit 

 

-

Search for new unit 

Install wireless units 

 

-

Pressure drop measurement 

Automatic pressure drop measurement   

ON

Volume measurement 

Requires a water meter with digi. output port     

OFF

- Volume per pulse 

Set depending on water meter 

 

1L/PULSE

- Volume limit 

At which water volume should turn OFF   

500L

Temperature limit 

At which temperature should the water be turned off.

 

OFF, 1, 2, 3, 4, 5 degrees 

 

3 degrees

External alarm 

Settings for external control 

 

ON/OFF

2.4.1.  Connected units

In order to handle the function of already connected units, you can use the following menu selection.
First select which unit you wish to manage “Select unit” and press OK, then move down to the 
desired function.  
“RSSI”, Indicates the signal strength of the most recent radio communication.
“TEMPERATURE”, Shows current temperature, Only applies to water sensors.  
“BATTERY LEVEL”, Shows current battery voltage and whether this is OK.
“Change name?”, easily change the name of a unit by moving down using the right/left arrows and 
confirm by pressing OK.
“Remove?”, used to remove connected units.

Note!

 If a unit is no longer in use, it needs to be permanently removed from the system, if not, the 

system will automatically expect the “I’m alive” signal from the unit every 24 hours and the central 
unit will trigger the alarm with a “beep” signal every three minutes after three days, “LOST CONTACT”, 
“DISHWASHER”.

2.4.2.  Search for new device

Upon installation of an additional remote unit or water sensor to expand the system, you can use 

Summary of Contents for WaterFuse - House

Page 1: ...1 20 WaterFuse House User Manual Installation Instruction...

Page 2: ...l carefully and follow the instructions for placement and usage The product may only be connected by a qualified installer The warranty does not cover repairs of faults caused by faulty installation o...

Page 3: ...tallation Instructions 11 2 1 General Information 11 2 2 Installation 12 2 3 Connection to house alarm system or other remote control 14 2 4 Settings 16 2 4 1 Connected units 16 2 4 2 Search for new d...

Page 4: ...e detector but for water If they indicate water a signal is sent to the central unit which automatically shuts off the water There is also a temperature sensor in the water detectors that can be used...

Page 5: ...ures current water pressure in the property s water system It can also be manually operated with a mechanical knob on the unit if the power goes out Lift the knob 5 mm and turn clockwise to close the...

Page 6: ...to stay on for a limited period of time press the button delayed OFF The water stays on for the period set on the central unit where you can choose 1 4 hours The water is then turned off in the entire...

Page 7: ...rt searching for water by the triggered water sensor Press Confirm when the fault has been rectified and the water can be turned back on Temperature Alarm If the temperature around any water sensor dr...

Page 8: ...unication This is usually because something has changed in the home since the last time the radio communication was functioning It could for example be because there are too many metal containers unde...

Page 9: ...y This allows your dishwasher or washing machine programme to finish even if you leave Can be set to 1 4 hours with 2 hours as the standard 2 Start Water OFF or RESET When the unit is started for exam...

Page 10: ...it must be remedied by the user or by a plumber If you are unable to locate the lead contact your plumber for troubleshooting Tips for troubleshooting Water faucets The check is most easily conducted...

Page 11: ...erence measure when the ball valve has closed after the user has turned the water off using the OFF delayed OFF or alarm The system then waits 15 minutes before taking the next and final measurement I...

Page 12: ...e article number and manufacturing date 2 2 Installation Water unit The unit is intended for tap water 0 60 C and 0 10 bar Fitted after the water meter and the main water line with the motorised ball...

Page 13: ...mote Unit art no 2220022 Place in an easily accessible place near an outer door Check so that no electrical cables or installations are found within 50 cm of the equipment as this disturbs the radio t...

Page 14: ...stallation mode the signal strength of the transmission can easily be checked Go into menu Advanced settings and then Connected units Select unit and move down to RSSI A value lower than 60DBM is exce...

Page 15: ...nected as follows Jumper between Pin 8 and Pin 4 Connect of the alarm to Pin 3 and of the alarm to Pin 7 In case of alarm indication Pin 3 will be 12v Digital 1 Preferably connected as follows GND One...

Page 16: ...FF 500L Temperature limit At which temperature should the water be turned off OFF 1 2 3 4 5 degrees 3 degrees External alarm Settings for external control ON OFF 2 4 1 Connected units In order to hand...

Page 17: ...select ON If you only want the pressure test to be conducted when the user has turned off the water select OFF 2 4 4 Volume Measurement If a water meter with a digital output port is connected to the...

Page 18: ...them back into place The units will then start with a beep in the installation mode and transmit every 15 seconds for five minutes This makes it easier to see if the transmission effect is sufficient...

Page 19: ...ead the operating instructions and if possible check that all settings are correct The warranty stipulates that defective parts or components will be replaced with defect free ditto The customer is re...

Page 20: ...20 20 Tel 018 34 90 10 info tollco se www tollco se Tollco AB Rubanksgatan 4 741 71 KNIVSTA...

Reviews: