Notification
Priority
Description
TestMessage
Test
This is a test message since the 'test' command was given as
RAID startup. This message will also be generated in the
event that the RAID Admin email address was changed to test
the new email address given.
This email can be deleted and the rest of this message can be
ignored.
MoveSpare
Informational
A spare drive has been moved from one array in the spare-
group to another to allow a failed drive to be replaced.
No further action is required by you at this time.
NewArray
Informational
A new RAID device has been detected in on the bruAPP
Backup Appliance.
No action is needed from you at this time.
RebuildStarted
Informational
The RAID array has begun the process of rebuilding. This
can occur when a component of the RAID fails and the spare
is started or when a failed component has been replaced and
the spare is being returned to 'spare' status.
No further action is required by you at this time.
Rebuild
Informational
The RAID has completed __ percent of the rebuild process.
Updates are periodically given at regular intervals. A final
message will be sent when the rebuild process is completed.
No further action is required on your part at this time.
RebuildFinished
Informational
The RAID array that was rebuilding is no longer rebuilding.
Either because the rebuild completed successfully or because
it was aborted.
If the rebuild was aborted, an additional notification message
will be sent following this message.
No action is needed from you at this time.
SpareActive
Informational
A spare component device, which was being rebuilt to replace
a faulty device, has been successfully rebuilt and has become
active.
No further action is required by you at this time.
Degraded
Warning
The RAID array appears to be degraded.
At this time you should take appropriate actions to repair the
disk in the RAID array that has caused the RAID to run in
degraded mode.
37