Toledo Brake Monitor Installation And Operation Manual Download Page 3

 

 

 

 

 

Doc #0017289 

Brake Monitor Operator Manual  

 

 
 
 
 
 
 
 

 

 
 
 

Brake Monitor 

Operator Manual 

 

Revision: 3.0 

 
 

 
 
 
 
 
 
 
 

 
 

Summary of Contents for Brake Monitor

Page 1: ...Brake Monitor Toledo Integrated Systems Toledo Transducers Inc Installation and Operation Manual...

Page 2: ...Doc 0017289 Brake Monitor Operator Manual...

Page 3: ...Doc 0017289 Brake Monitor Operator Manual Brake Monitor Operator Manual Revision 3 0...

Page 4: ...xpressed or implied including without limitation any warranties of merchant ability or fitness for particular purpose All such warranties are hereby disclaimed and excluded by the manufacturer Repair...

Page 5: ...HOME SCREEN 6 2 1 POS Position 6 2 2 SPM Strokes Per Minute 6 2 3 Counters 6 2 4 Status Message 6 2 5 Back Key Reset Counters 7 SECTION 3 MENU SELECT SCREEN 8 SECTION 4 VIEW BRAKE MONITOR 9 SECTION 5...

Page 6: ...0017289 Brake Monitor Operator Manual Page 3 TABLE OF CONTENTS APPENDIX A DRAWINGS BRAKE MONITOR TERMINAL STRIP LAYOUT I ENCODER CABLE WIRING II ENCODER DIMENSIONS III BRAKE MONITOR MOUNTING DIMENSION...

Page 7: ...al 1 1 ADJUSTING THE CONTRAST If the screen is either too dark or too light the contrast can be adjusted by pressing and holding the ENTER key and pressing either the up or down arrow key To darken th...

Page 8: ...additional settings or return control to a specified screen 1 5 RESET KEY The red RESET Key is used to reset any faults that occur Refer to Section 8 Faults for an explanation The RESET Key is also us...

Page 9: ...his will display the current strokes per minute 2 3 COUNTERS Parts Counter This will display the number of parts produced since the last Parts Counter reset occurred For an explanation of how to reset...

Page 10: ...ess the red RESET key when the cursor is next to the Parts Counter Value To move the cursor to the Stroke Counter press the ENTER key STROKE To reset the Stroke Counter press the red RESET key when th...

Page 11: ...onitor Edit Brake Monitor 90 DEG BRAKE TEST and System Setup To protect the system settings a password is required for all functions except View Brake Monitor A selection can be made by either using t...

Page 12: ...tor settings access the Menu Select Screen select View Brake Monitor and press the ENTER key You will be taken to the following screen This screen shows the last Stop Time and the Allowable Stop Time...

Page 13: ...e Menu Select Screen select Edit Brake Monitor and press the ENTER key The following screen will appear Type the password using the alpha numeric keys then press the ENTER key If the wrong password is...

Page 14: ...range for Allowable Stop Time is 0 1000 milliseconds i e 1000mS 1 Second When the correct Allowable Stop Time is displayed press the ENTER key Press the BACK key to return to the Menu Select screen If...

Page 15: ...PASSWORD Either retry to enter the correct password or press the BACK key to return to the Menu Select Screen After the correct password has been entered the 90 DEG BRAKE TEST screen shown above will...

Page 16: ...ntinuous or single mode 4 Run the main motor at its fastest speed 5 Press 0 to activate the brake test 6 Run the press 7 When the press passes 90 degrees the immediate stop output will open up giving...

Page 17: ...WORD Either retry to enter the correct password or press BACK to go back to the Menu Select Screen NOTE The Global Password is used to access this screen After the correct password has been entered th...

Page 18: ...t direction If it is not switch the A and B Encoder wires 2 Inch the press around at least one full stroke to make sure that the Z pulse has cycled 3 Inch the press to a known position the most common...

Page 19: ...set all the settings in the entire unit to factory default A confirmation screen will be displayed Press the red RESET key to continue to restore the factory defaults A message confirming that the def...

Page 20: ...ccess to all functions except for Edit Brake Monitor and System Setup 2 Global This level gives the user access to all functions of the Brake Monitor The unit comes factory set with the passwords disa...

Page 21: ...blinking Enter a new value by using the alpha numeric keys The valid range for Allowable Stop Time is 0 5000 milliseconds i e 5000mS 5 Seconds When the correct Allowable Start Time is displayed press...

Page 22: ...l need to be repeated to clear that fault 8 1 DRIFT FAULT A Drift Fault occurs when motion is detected on the encoder without the clutch valve engaged 8 2 NO MOTION FAULT When the clutch valve is enga...

Page 23: ...Doc 0017289 Brake Monitor Operator Manual Page 20 USER NOTES...

Page 24: ...Doc 0017289 Brake Monitor Operator Manual Page 21 USER NOTES...

Page 25: ...Doc 0017289 Brake Monitor Operator Manual Page 22 REVISION HISTORY 4 2013 REV 3 0 Initial Release...

Page 26: ......

Page 27: ......

Page 28: ......

Page 29: ......

Reviews: