![Toledo Brake Monitor Installation And Operation Manual Download Page 21](http://html1.mh-extra.com/html/toledo/brake-monitor/brake-monitor_installation-and-operation-manual_1125218021.webp)
Doc #0017289
Brake Monitor Operator Manual
Page 18
SECTION 7
SYSTEM SETUP
7.4 NO MOTION
After selecting No Motion from the System Setup Menu, the user will be able to change
the Allowable Start Time. The Allowable Start Time value will be blinking. Enter a new
value by using the alpha-numeric keys. The valid range for Allowable Stop Time is 0-
5000 milliseconds (i.e. 5000mS=5 Seconds). When the correct Allowable Start Time is
displayed, press the
<ENTER>
key. Press the
<BACK>
key to return to the Setup Menu.
If the Start Time (the time it takes from when the power to the clutch valve is applied,
until the ram starts moving) is longer than the Allowable Start Time, an alarm will occur.