![Toledo Brake Monitor Installation And Operation Manual Download Page 14](http://html1.mh-extra.com/html/toledo/brake-monitor/brake-monitor_installation-and-operation-manual_1125218014.webp)
Doc #0017289
Brake Monitor Operator Manual
Page 11
SECTION 5
EDIT BRAKE MONITOR
After entering the correct password, you will see the Edit Brake Monitor screen (shown
below). The Allowable Stop Time value will be blinking. Enter a new value by using
the alpha-numeric keys. The valid range for Allowable Stop Time is 0-1000 milliseconds
(i.e. 1000mS=1 Second). When the correct Allowable Stop Time is displayed, press the
<ENTER>
key. Press the
<BACK>
key to return to the Menu Select screen.
If the Stop Time (the time it takes from when the power to the clutch valve is removed,
until the ram comes to a complete stop) is longer than the Allowable Stop Time, an alarm
will occur. To set the Allowable Stop Time, the Global Password must be entered from
the Menu Select Screen.