![Tokyo Gas Engineering Solutions Corporation Laser Methane Mini Operation Manuals Download Page 20](http://html1.mh-extra.com/html/tokyo-gas-engineering-solutions-corporation/laser-methane-mini/laser-methane-mini_operation-manuals_1125159020.webp)
xviii
3. Applied Standards
EMC: Emission: EN61326-1: 2013
Immunity: EN61326-1: 2013
SA3C32A
SA0Z42A
Performance
Criteria*
IEC61000-4-2 (ESD)
–
√
B
IEC61000-4-3 (EMF)
√
√
A
IEC61000-4-4 (Burst)
–
–
B
IEC61000-4-5 (Surge)
–
–
B
IEC61000-4-6 (CRF)
–
–
A
IEC61000-4-8 (RPFMF)
–
–
A
IEC61000-4-11 (V dip/short)
–
–
C
*: Performance Criteria
A: Normal performance within the specification limits during testing.
B: Temporary degradation, or functional loss, which self-recovers
during testing
C: Temporary functional loss is allowed, provided that the function is
self-recoverable or the operational control can be restored.
The power consumption of the AC ADAPTER is 29.70W, which is less than
75W and no limits apply. Therefore it is deemed to comply with EN61000-3-2
without any testing.
ATEX: EN60079-0: 2012
EN60079-11: 2012
EN60079-28: 2007