Tokyo Gas Engineering Solutions Corporation Laser Methane Mini Operation Manuals Download Page 2

 

Summary of Contents for Laser Methane Mini

Page 1: ...Laser Methane SA3C32A Read this manual before using the equipment Keep this manual with the equipment Operation Manual Tokyo Gas Engineering Solutions Corporation...

Page 2: ......

Page 3: ...the user if this symbol is ignored and operation is not performed properly This indicates contents that could result in serious injury or death for the user if this symbol is ignored and operation is...

Page 4: ...June 2015 Seventh Edition All rights reserved No part of this manual may be reproduced without the prior written permission of the publisher The contents of this manual may be changed without prior no...

Page 5: ...e is broken as this may cause fire or electric shock Immediately take the Actions indicated below Do not use the product if water or foreign objects have gotten inside Continuing to use the product un...

Page 6: ...anual Do not store or carry the battery pack together with metal objects such as coins keys or chain Do not dismantle damage or heat the outer body chassis of the battery pack Do not throw the battery...

Page 7: ...s it bend it forcefully pull on it twist it roll it up cover it with heavy objects fix it with nails or wire or heat it up Do not connect the AC cord to a multi outlet such as a cable tap or a current...

Page 8: ...the display screen to break Do not use the product and battery charger in locations where heat builds up because this may cause fire Be sure to observe the following points Do not charge the unit on...

Page 9: ...becomes hot during charging Be careful when handling it Do not keep looking at the detection lamp for a long time This may cause dazzling which can possibly cause a secondary accident In case the det...

Page 10: ...ly hot locations such as inside a car or in cold locations directly exposed to outside air Avoid storing the product in locations where it can be exposed to strong vibrations Storing the battery pack...

Page 11: ...ailure Without using the product please call customer service to request repair Do not view laser radiation from Class 2 laser products directly with optical instruments because the laser radiation mi...

Page 12: ...th CW Wavelength 1653nm Beam extension in collimated beam 8 5mrad or less Guide light beam radiation Class 2 Laser Maximum output power 1mW or less Pulse width CW Wavelength 650nm Beam extension in co...

Page 13: ...efore making any repair or modifications to an equipment This equipment including SA0Z40A Battery Pack has been tested and certified as being intrinsically safe or explosionproof Please note that seve...

Page 14: ...losive atmospheres except the approved category Using this equipment at the Zone 0 for city gas etc is strictly prohibited DO NOT charge the battery pack in explosive atmospheres The battery charger i...

Page 15: ...60079 11 2012 EN60079 28 2007 Type of Protection and Marking code Group I and II Category M2 and 2G Ambient Temperature 17 to 50 C Applicable detection hazardous areas Zones 1 and 2 for city gas etc...

Page 16: ...safety recycle the battery packs that are no longer used after discharging them in procedures as follows Insert the battery pack in the main unit Switch on the power of the main unit Until the empty s...

Page 17: ...sed by improper or insufficient maintenance on the part of the customer Unavoidable faults arising from fires floods earthquakes other acts of God etc Faults caused by connecting any other products pa...

Page 18: ...fficient precautions against static electricity Please use this product in an environmemt where sufficient measures are implemented against static electricity This product is an intrinsically safe pro...

Page 19: ...93 68 EEC to indicate that they conform to the EMC and ATEX Directive of the European Union EU CE marking 1 Product Model Model SA3C32A LaserMethane mini and Accessories SA0Z40A BATTERY PACK SA0Z41A...

Page 20: ...ormal performance within the specification limits during testing B Temporary degradation or functional loss which self recovers during testing C Temporary functional loss is allowed provided that the...

Page 21: ...ation to indicate that they conform to the EMC framework of Australia New Zealand C tick marking 1 Product Model Model SA3C32A LaserMethane mini and Accessories SA0Z40A BATTERY PACK SA0Z41A PROTECT CO...

Page 22: ...or Administration of the Pollution Control of Electronic Information Product of the People s Republic of China They are applicable only in the People s Republic of China Pb Hg Cd Cr PBB PBDE PCA Chass...

Page 23: ...xxi 2006 2 28 SJ T 11364 2006 5...

Page 24: ......

Page 25: ...l This operation manual describes how to use and maintain the SA3C32A LaserMethane mini hereinafter this product Chapter 1 describes Outline and Principle and the following sections provide more detai...

Page 26: ......

Page 27: ...Nomenclature 4 3 1 Main unit 4 3 2 Display 5 4 Preparations Before Use 6 4 1 Charging Battery Pack 6 4 2 Attaching Strap 8 4 3 Attaching Battery Pack 9 5 Operation Method 10 5 1 Starting Up and Ending...

Page 28: ...Maintenance 31 8 1 Maintenance Method 31 9 Main Specifications 32 9 1 Main Specifications of Main Unit 32 9 2 Main Specifications of Battery Charger and AC Adapter 33 10 Ordering Information 34 10 1 M...

Page 29: ...red value of methane is displayed on the display in real time 1 2 Principle This product is based on Infrared Absorption Spectroscopy using a semiconductor laser for methane detection The integrated c...

Page 30: ...inciple to gases other than methane butane propane etc This product cannot perform detection in places where detection laser beam cannot reach such as the opposite side of a wall or underground Above...

Page 31: ...e sure that you have received all the items listed below If there are any missing or damaged items immediately contact Customer Service Main unit Standard Accessories Main unit 1 unit Battery pack 1 p...

Page 32: ...Main unit Light receiver Measurement light output window Guide light output window Power button Start Stop button Display Back button Menu Enter button buttons Display Battery pack fixing screw Batter...

Page 33: ...yed when laser beam is on Maximum measured value during continuous operation Measured value Meter display of current measurement value Battery Mark Alarm level Unit ppm m vol m LEL m Alarm level Refle...

Page 34: ...ely all the way to the end Explanation of LED display of battery charger The orange LED when lit indicates that charging is in progress The green LED when lit indicates that charging has been complete...

Page 35: ...battery pack and the battery charger may become hot during charging Use the dedicated battery pack SA0Z40A only with the dedicated battery charger SA0Z42A Do not use an AC adapter such as a car charg...

Page 36: ...ery pack has reached the end of its service life Replace the battery pack with a new one This figure is a guideline based on JIS C8708 test conditions The actual number of cycles may differ according...

Page 37: ...battery pack 1 Loosen the two battery pack fixing screws at the base of the battery pack 2 Remove the battery pack by pulling it sideways to the mark on the main unit and then pull it up Two months or...

Page 38: ...ostic test for accurate measurement After the startup and self test if you set the 1 Enable in the 8 Gas test on the SETTINGS screen the proceeding screen for the gas test to be performed by the custo...

Page 39: ...11 Switching off the power 1 Press the Power button for approximately 2 seconds The product will emit a beeping sound 2 The screen will switch off...

Page 40: ...umeric mode graph mode 3 To end measurement press the Start Stop button again During measurement the measured and maximum values are displayed every 0 5 seconds and when measurement ends the data is k...

Page 41: ...er beam is on while the LASER on the display is lit never direct the laser beam toward people or look into the laser beam output windows When not using this product be sure to switch it off WARNING WA...

Page 42: ...than 10mm please note that you may get wrong measurements if you keep pointing the laser directly at the PE pipe because laser light penetrates through depending on its thickness Figure A Possibility...

Page 43: ...product is powered on and on stand by 2 The SETTINGS screen shown on the right will be displayed 3 Select the item from 1 to 8 with the buttons and then press the Menu Enter button To return to the m...

Page 44: ...Enter button 5 The SETTINGS screen will be displayed 6 Select the item from 1 to 8 with the buttons and then press the Menu Enter button To return to the FUNCTION SELECTION screen press the Display Ba...

Page 45: ...it 10 s digit and 1 s digit 4 Once the setting for the 1 s digit is completed the buzzer sounds twice to indicate that the setting has been accepted 5 Your set value will be displayed on the numeric m...

Page 46: ...for the 10 s digit and 1 s digit 4 Once the setting for the 1 s digit is completed the buzzer sounds twice to indicate that the setting has been accepted 5 OFFSET is shown on the bottom of the displa...

Page 47: ...nu Enter button 4 The set value will be shown on the bottom of the display The set value will not be reset even when the power is switched off 4 Screen Brightness In the main menu select 4 Display 1 T...

Page 48: ...will not be reset even when the power is switched off 6 Detection Lamp The detection lamp flashes when the methane column density is over the set Alarm Level In the main menu select 6 Detect lamp 1 Th...

Page 49: ...buttons 3 Press the Menu Enter button When the 3 LEL m is selected in the upper right screen the Unit screen shown on the right will be displayed The lower explosion limit value indicated by the colu...

Page 50: ...contact Customer Service or your local sales agent About proceeding to the gas test refer to the 5 6 Gas test by customer for details In the main menu select 8 Gas test 1 The GAS TEST screen shown on...

Page 51: ...s 4 Press the Menu Enter button 5 Automatic calibration will start and for 2 to 3 minutes the AUTO CALIBRATION screen shown on the right will be displayed The progress status can be checked with the c...

Page 52: ...k shown on the display indicates the battery pack residual power When the battery power of the battery pack is lost until this product doesn t operate the empty screen shown on the right will be displ...

Page 53: ...rmance screen shown on the right will be displayed 4 The result will be shown About the proceedings of the gas test methane concentration and the approved gas cell contact Customer Service or your loc...

Page 54: ...4 Automatic Calibration If the same error message is displayed repeatedly request repair CAUSE The product is not in a measurement enabled state When SELF TEST FAILURE is displayed 1 Switch off the po...

Page 55: ...erformed correctly When PARAMETER ERROR is displayed 1 Switch off the power of the product 2 After checking that the power is switched off switch on the power If the same error message is displayed re...

Page 56: ...of the product so that external light such as sunlight does not get in the unit Change the detection point so that strong light does not get in the unit CAUSE Strong light such as sunlight is getting...

Page 57: ...arting Up and Ending Is the battery pack sufficiently charged Use a fully charged battery pack See 4 1 Charging Battery Pack No measurement beep sound is emitted Has the SOUND LEVEL setting been set t...

Page 58: ...k correctly attached to the battery charger See 4 1 Charging Battery Pack Are the battery charger AC adapter AC cord and power outlet correctly connected See 4 1 Charging Battery Pack Is the red LED o...

Page 59: ...8 Daily Maintenance 8 1 Maintenance Method If the laser beam output window and the light receiver of the product are soiled gently wipe them clean with a dry soft cloth being careful not to scratch th...

Page 60: ...Guide light Measurement light IEC60825 1 JIS C6802 Output wavelength 650nm Output level 1mW Class 2 or less Output wavelength 1653nm Output level 10mW Class 1 or less NEVER LOOK INTO THE LASER BEAM I...

Page 61: ...hrs Operating temperature 5 35 C Operating humidity 30 90 No dew condensation Storage temperature 10 60 C Storage humidity 90 or less AC adapter input voltage 100 240VAC AC adapter output voltage 12VD...

Page 62: ...Remarks SA3C32A SA0Z40A SA0Z42A SA0Z47C SA0Z44B SA0Z41A LaserMethane mini Battery pack 1 pc Battery charger 1 unit AC Adapter Set EU 1 unit Strap Long type 1 pc Protect cover 1 pc Operation manual 1...

Page 63: ...mer Service or to your local sales agent 11 1 Customer Service Equipment Sales Department Tokyo Gas Engineering Solutions Corporation 4F Nissey Aroma Square 5 37 1 Kamata Ota ku Tokyo Japan 144 8721 T...

Page 64: ...lutions Corporation 4F Nissey Aroma Square 5 37 1 Kamata Ota ku Tokyo Japan 144 8721 TEL 81 3 5480 6850 FAX 81 3 5480 6851 URL http www tokyogas es co jp en company index html 12 2 Manufacture Anrisu...

Page 65: ...Tokyo Gas Engineering Solutions Corporation Equipment Sales Department 4F Nissey Aroma Square 5 37 1 Kamata Ota ku Tokyo Japan 144 8721 TEL 81 3 5480 6850 FAX 81 3 5480 6851 Service Support Section...

Page 66: ...Management number AD L0009CZ013 06...