![Tohnichi CSPFHW Operating Instruction Download Page 20](http://html1.mh-extra.com/html/tohnichi/cspfhw/cspfhw_operating-instruction_1124733020.webp)
20
Radio Frequency
Torque W
rench with Double
Tightening Detection
Input double tightening judgment point of angle degree
Select ON or OFF this function
ON: Wrench sends signal with 3-digits of double tightenng NG ID.
OFF: Wrench indicates error message on LED only, signal will not
be emited to receiver.
3-digits signal when the double tightening has been occured.
* Available when double tightening NG signal setting is ON.
* By setting the double tightening NG ID to the surplus relay
output ports of a receiver, it is available to send a NG relay signal
to an external device.
* If the same number is set as 3-digits ID and double tightening
ID, the receiver cannot identify the signal is double tightening NG
signal or not.
[Description of various settings]
- Double tigtening detection
angle degree
- Double tightening NG signal
- Double tightening 3-digits ID
Settings for Double Tightening Judgment