SPECIFICATIONS

GENERAL INSTALLATION DATA

PLACE THE LAMINATED WARNING SIGN SUPPLIED WITH THE FRYER IN AN AREA 

VISIBLE TO THE FRYER OPERATOR. 

This equipment is designed and sold for commercial use only by personnel trained and 
experienced in its operation and is not sold for consumer use in and around the home nor for use 
directly by the general public in food service locations.

Before using your new equipment, read and understand all the instructions & labels associated 
with the unit prior to putting it into operation.  Make sure all people associated with its use 
understand the units operation & safety before they use the unit.

All shipping containers should be checked for freight damage both visible and concealed.  This 
unit has been tested and carefully packaged to insure delivery of your unit in perfect condition.  If 
equipment is received in damaged condition, either apparent or concealed, a claim must be made 
with the delivering carrier.

Concealed damage or loss - if damage or loss is not apparent until after equipment is unpacked, 
a request for inspection of concealed damage must be made with carrier within 5 days.  Be 
certain to retain all contents plus external and internal packaging materials for inspection.  The 

carrier will make an inspection and will supply necessary claim forms.

The installation of the Appliance should conform to the NATIONAL FUEL GAS CODE 

"ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND 

REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/ 

CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2 PROPANE 

INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.

WARNING: 

Improper  installation,  adjustment,  alteration,  service  or  maintenance 

can  cause  property  damage,  injury  or  death.    Read  the  installation,  operating  and 
maintenance instructions thoroughly before installing or servicing the equipment.

This appliance and control valve must be disconnected from the gas supply piping system during 
any pressure testing of that system at test pressures in excess of /2 PSIG (.034 ATM).  This 
appliance must be isolated from the gas supply piping system by closing its individual manual 
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal 

to or less than 1/2 PSIG (1.034 ATM).  For your protection, we recommend a qualified installing 

agency install this appliance.  They should be familiar with gas installations and your local gas 

requirements.  In any case, your gas company should be called to approve the final installation.  

In addition, there should be posted, in a prominent location, detailed instructions to be followed in 
the event the operator smells gas.  Obtain the instructions from the local gas supplier.

FRYER SHOULD BE RESTRAINED TO PREVENT TIPPING WHEN INSTALLED TO 

AVOID SPLASHING OF HOT LIQUID.  USE ADEQUATE TIES WHEN INSTALLING 

THE FRYER.

CAUTION

CAUTION

Model

Height x Width x Depth

Gas Connection

NAT / LP 

Weight

Installed

Shipped

TMFG18

25.625” x 12” x 25”

3/8” NPT

24,000 BTU/HR

64 lbs

73 lbs

62.6cm x 30.5cm x 61cm

1cm NPT

29 kg

33.1 kg

TMFG30

23.375” x 24” x 25.125”

1/2” NPT Female

NAT:70,000 BTU/HR

110 lbs

118 lbs

59cm x 61cm x 64cm

2cm NPT Female

LP:65,000 BTU/HR

50 kg

54 kg

Summary of Contents for TMFG18-LP

Page 1: ...MFG18 GAS FRYERS MODEL TMFG18 NAT TMFG18 LP TMFG30 NAT TMFG30 LP Installation and Operation Instructions 2M Z13008 Rev Oct 1 2009 is a registerd trademark of Toastmaster A Middleby Company All rights...

Page 2: ...s in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks in connection with such use MAINTENANCE AND REPAIR...

Page 3: ...ORDANCE WITH THE CURRENT CAN CGA B149 1 NATURAL GAS INSTALLATION CODE OR CAN CGA B149 2 PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE WARNING Improper installation adjustment alteration s...

Page 4: ...nected to existing piping it shall be checked to determine if it has adequate capacity Joint compound pipe dope shall be used sparingly and only on the male threads of the pipe joints Such compounds s...

Page 5: ...r increase pilot flame Flame must surround thermocouple tips by approximately 1 2 1 2cm 4 Replace slotted screw cap tightly to prevent gas leakage THERMOSTAT RECALIBRATION 1 Todeterminewhetherornotthe...

Page 6: ...the crumb tray in the kettle when the fat has melted BASKET RACK Model TMFG18 Place the rack before adding fat 7 Turn the thermostat knob to the desired frying temperature DO NOT FRY MORE FOOD PER BA...

Page 7: ...in excess of 385 F 196 C 3 DO NOT overfill your fry kettle 4 DO NOT allow burned crumbs to accumulate 5 DO melt solid fat or shortening before filling fryer 6 DO keep kettle filled to capacity at all...

Page 8: ...contacts the skin Hot oil is ammable Keep open ames away from hot oil and its vapors Never allow water or ice to get in hot oil IT CAN EXPLODE WARNING ENVIRONMENT Keep your oors clean and free of gre...

Page 9: ...caused by frying too long at too low temperatures One answer to both problems is exact control of heat so that fat neither smokes up nor soaks up Of course no fat keeps forever Not only heat but air...

Page 10: ...ops Breading 350 4 Shrimp Batter Some prefer soaking 1 2 hour in cold seasoned milk 350 3 Smelts Breading Cut spinal cord several 350 4 places to prevent curling MEATS Chicken Fried Steak Breading Sev...

Page 11: ...E DR THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG INT L INC NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED 10 SUNNEN DRIVE ST LOUIS MO 63143 USA A 3 25 03 ADDED WIRE ASSY NO...

Page 12: ...13 MODEL TMFG18 Gas Fryer SK2435 REV 9 02 09 7 4242 6 9370 23 24 22 16 27 26 28 17 15 14 13 12 10 9 25 1 8 7 6 5 4 3 2 39 38 37 36 35 34 33 32 31 30 11 29 40 20 18 19 21 41 42 43 44...

Page 13: ...5 1 PILOT NAT 016 ORIFICE NAT E4 Z0556 PILOT PROP 026 ORIFICE LP 11 E4 404040 1 MANIFOLD ASSY 12 E4 404034 1 RETAINER HINGE 13 E4 404051 1 BASIC ASSY TMFG18 14 E4 Z0086 1 PANEL RIGHT 15 E4 404032 1 TR...

Page 14: ...lable is a registerd trademark of Toastmaster A Middleby Company All rights reserved Fig No Part No Qty Description Application 40 2J Y9977 1 LPT PRESSURE REGULATOR OPTIONAL FOR PROPANE 41 E4 Z0554 1...

Page 15: ......

Page 16: ...TMFG30 Gas Fryer SK2436 REV 9 02 09 7 5 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 BODY ASSY COMBUSTION CHAMBER 4...

Page 17: ...690 1 PILOT NATURAL GAS 10 E6 Y9691 1 PILOT PROPANE 11 2T Y9266 1 SAFETY THERMOSTAT 13 E6 Z1441 2 HANDLE 14 E6 Y9879 1 DOOR PANEL 15 2A 9368 6 ORIFICE LP 61 15 E6 Y9943 6 ORIFICE NAT 50 16 E2 215024 6...

Page 18: ...lable is a registerd trademark of Toastmaster A Middleby Company All rights reserved Fig No Part No Qty Description Application 42 E6 Y9951 1 SHIELD VALVE 43 2J 7961 1 E Z LIGHTER ROD 44 2J Y9977 1 LP...

Page 19: ...that is not pre approved and performed by a Toastmaster authorized service agent Any such service immediately voids this warranty This warranty does not apply to any parts labor and material expenses...

Page 20: ......

Page 21: ...rasse de la friteuse pendant que la mati re grasse est ti de et non chaude 2 Rincer pour faire dispara tre les miettes et tous les r sidus qui n adh rent pas 3 Remplir d eau Porter bullition et ajoute...

Page 22: ...es c t s les tubes et le fond de la marmite pour liminer les miettes etc Continuer verser jusqu ce que toutes les miettes etc soient entra n s dans le sac filtre Retirer le sac filtre et le laver pour...

Page 23: ...utiliser un niveau plus lev de mati re grasse pour faire frire des aliments volumineux tels que des croquettes de poisson ou de poulet Le niveau doit tre choisi soigneusement de mani re ce que l acti...

Page 24: ...rmostat doit ou non tre r talonn utiliser un thermom tre exact situ environ au centre de la marmite avec le bulbe plac 2 4 cm sous le dessus du gras 2 Mettre le thermostat 177 o C et v rifier le relev...

Page 25: ...ds sont exempts de salet interne non adh rente Ne pas enlever le scellement avant le raccordement effectif aux conduites d approvisionnement en gaz RACCORDEMENT LA CONDUITE D APPROVISIONNEMENT EN GAZ...

Page 26: ...gaz durant tout essai de pression de ce syst me des pressions d essai de plus de 1 2 PSIG 1 034 ATM Cet appareil doit tre isol du syst me d approvisionnement en gaz en fermant sa soupape individuelle...

Page 27: ...s dans ce manuel sont susceptibles de changer sans pr avis Quoique Toastmaster exerce la bonne foi de fournir le renseignement correct Toastmaster n est pas responsable pour les erreurs ou les omissio...

Page 28: ...OMPTOIR Models TMFG18 NAT TMFG18 LP TMFG30 NAT TMFG30 LP Instructions d installation et d op ration 2M Z13008 Rev Oct 1 2009 est une marque de Registerd Toastmaster la Compagnie A Middleby Tous droits...

Reviews: