6. NOMENCLATURE AND FUNCTIONS

[Front] 

1. Torx Screw

Use Torx Screwdriver: Size T10 to screw or to 

unscrew the substation.

2. Speaker

Outputs call tones and used for hands-free 

conversations. 

Protected against attacks by 

means of wires or fluids. 

3. Operation Indicator

Lights as long as the unit is connected to the 

exchange.

4. Emergency Push Button 

The  button  is  protected  by  a  protective  pane.        

In case of emergency this pane has to be 

smashed.

5. Standard Push button

Used to call the pre-programmed master station. 

(See 

p. 8

)

6. Microphone

Used for hands-free conversation. 

For both 

Emergency and Standard conversation. The 

microphone will be opened after the call was 

received.

7. Connection terminal [Earth] 

Connects to Earth

8. Connection terminal [1-4] 

Connects to the N-8400RS exchange. (Terminal 

block) (See 

p. 7

9. Ground terminal  

Connects to Ground of OW-101

[Rear]

Summary of Contents for RS-410EC e

Page 1: ...com Station Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment Note For operation of the units refer to the N 8000 series operating instructions...

Page 2: ...ng be sure to grasp the plug never pull on the cord itself Operating the unit with a damaged cord may cause a fire or electric shock Avoid installing the unit in dusty locations or in locations expose...

Page 3: ...ded for informational calls It features 2 different programable call targets each one individual target per button Emergency calls are listed in position one of the call queue on the master station N...

Page 4: ...exchange 4 Emergency Push Button The button is protected by a protective pane In case of emergency this pane has to be smashed 5 Standard Push button Used to call the pre programmed master station Se...

Page 5: ...sing of a button does not direct the call to another station After the call has been proceeded and finished a new call can be processed A smashed pane is to be replaced by a new pane spare part 7 1 2...

Page 6: ...tions where it gets splashed with water Recommended Back Boxes for RS 410EC are either for flush mounting IW 101 or for surface mounting OW 101 Provide a weep hole at the bottom of the mounting box to...

Page 7: ...sing a stran ded wire Step 2 Loosen the terminal screws and insert the cables Step 3 Tighten the terminal screws securely Notes Tug lightly on the cable to be sure that it does not pull free If the ca...

Page 8: ...be registered via the Model Name RS 442 The system mode shall be Selective Response 10 1 Programming the LED of emergency push button lit if the emergency button was pressed Activate Calling Station I...

Page 9: ...DIMENSIONAL DIAGRAM Unit mm FRONT VIEW BOTTOM VIEW RS 410EC e Priority Call 1 1 low priority Call 2 5 emergency call high priority Call 3 Not available Call Master Call 1 Call Target for Standard Pus...

Page 10: ...ve pane Operation Indicator 1 LED Wiring Twisted pair cables 2x pair Transmission Range 1km 0 5mm AWG24 1 5km 0 65mm AWG22 2km 0 9mm AWG19 Installation Method Flush mount Surface mount Housing Protect...

Reviews: