12. SPECIFICATIONS

Note: Change of design and specifications without prior notice possible.  

• Options

Surface-mount box: OW-101  ...................................................  1 

Flush-mount box: IW-101 .........................................................  1 

Model

RS-410EC e

Rated Input

1 W

Audio Frequency Range

 300Hz – 7kHz

Speech Method

 Hands-free conversation

Hands-free

Speaker: 3,5cm (1.38“) cone-type, maximum output 0,5W, 8Ω

Microphone: Omni-directional electret condenser microphone

Push-button Standard

Momentary, stainless steel, silver

Push-button Emergency

Momentary, red (blinks red during calling, lights during conversation)

Description Emergency

Protective pane

Operation Indicator

1 LED

Wiring

Twisted pair cables (2x pair)

Transmission Range 

1km / Ø 0,5mm (AWG24)

1,5km / Ø 0,65mm (AWG22)

2km / Ø 0,9mm (AWG19)

Installation Method

Flush-mount / Surface-mount

Housing Protection

IEC 62262: IK10

Dust/ Water Protection

EN 60529: IP 65. (panel edges must be sealed at installation)

Operating Temperature

-10°C to 50 °C

Operating Humidity

Under 90 % RH (condensation free)

Finish

Front plate: Aluminum

Call-buttons: Steel

Dimensions

150 (W) x 247 (H) x 45 (D) mm

Weight

0.6 kg

Traceability Information for Europe (EMC directive 2004/108/EC)

Manufacturer: 

TOA Electronics Europe GmbH 

Suederstrasse 282, 20537 Hamburg, Germany   

Authorised representative

TOA Electronics Europe GmbH 

Suederstrasse 282, 20537 Hamburg, 

Germany  

 http://www.toa.de/ 

833TEERZ1603b 

Summary of Contents for RS-410EC e

Page 1: ...com Station Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment Note For operation of the units refer to the N 8000 series operating instructions...

Page 2: ...ng be sure to grasp the plug never pull on the cord itself Operating the unit with a damaged cord may cause a fire or electric shock Avoid installing the unit in dusty locations or in locations expose...

Page 3: ...ded for informational calls It features 2 different programable call targets each one individual target per button Emergency calls are listed in position one of the call queue on the master station N...

Page 4: ...exchange 4 Emergency Push Button The button is protected by a protective pane In case of emergency this pane has to be smashed 5 Standard Push button Used to call the pre programmed master station Se...

Page 5: ...sing of a button does not direct the call to another station After the call has been proceeded and finished a new call can be processed A smashed pane is to be replaced by a new pane spare part 7 1 2...

Page 6: ...tions where it gets splashed with water Recommended Back Boxes for RS 410EC are either for flush mounting IW 101 or for surface mounting OW 101 Provide a weep hole at the bottom of the mounting box to...

Page 7: ...sing a stran ded wire Step 2 Loosen the terminal screws and insert the cables Step 3 Tighten the terminal screws securely Notes Tug lightly on the cable to be sure that it does not pull free If the ca...

Page 8: ...be registered via the Model Name RS 442 The system mode shall be Selective Response 10 1 Programming the LED of emergency push button lit if the emergency button was pressed Activate Calling Station I...

Page 9: ...DIMENSIONAL DIAGRAM Unit mm FRONT VIEW BOTTOM VIEW RS 410EC e Priority Call 1 1 low priority Call 2 5 emergency call high priority Call 3 Not available Call Master Call 1 Call Target for Standard Pus...

Page 10: ...ve pane Operation Indicator 1 LED Wiring Twisted pair cables 2x pair Transmission Range 1km 0 5mm AWG24 1 5km 0 65mm AWG22 2km 0 9mm AWG19 Installation Method Flush mount Surface mount Housing Protect...

Reviews: