6. TROUBLESHOOTING

Symptom

Possible cause

Remedy

Power indicator does not
light even if the power
switch is turned on.

• The AC adapter is not plugged into

a working AC outlet, or is not
plugged in correctly.

• AC adapter plug is not connected to

the charger.

• Make sure the AC adapter is

plugged in to a working AC wall
outlet correctly.

• Connect the plug to the charger's

power input terminal.

Charging indicator (red)
does not light even when
the infrared wireless
microphone is inserted
into the microphone
receptacle.

• The batteries used in the

microphone may not be dedicated
IR-200BT rechargeable batteries.

• The infrared wireless microphone

may not be seated correctly in the
microphone receptacle.

[For the IR-200M]
• The mounting adapter may not be

installed correctly.

• Install the appropriate dedicated IR-

200BT rechargeable battery in the
microphone.

• Make sure that the microphone is

inserted fully into charger as far as
it will go.

• Install the mounting adapter

correctly.

Inserting the infrared
wireless microphone into
the microphone receptacle
causes the charging
indicator (red) to flash.

• The ambient temperature may

exceed the permissible operating
temperature range (0 to 40 ºC, or
32 to 104 ºF), preventing charging.

• Perform charging within the

operating temperature range (0 to
40 ºC, or 32 to 104 ºF).

Full-charge indicator
(green) always lights soon.

• The dedicated IR-200BT

rechargeable battery has probably
reached the end of its life cycle
(usually after about 500 charges
and discharges).

• Replace the rechargeable battery

with a new one.

Full-charge indicator does
not light even 3 hours after
charging has been started
(maximum charging time:
3 hours).

• The infrared wireless microphone's

power switch may be set to ON.

• The battery may be at the end of its

life.

• Set the infrared wireless

microphone's power switch to OFF.

• Replace the rechargeable battery

with a new one.

Both the charging indicator
(red) and the full-charge
indicator (green) light
alternately.

• The microphone may have been

installed with a non-IR-200BT
rechargeable battery.

• There may be foreign objects (such

as metals) in the microphone
receptacle. 

• The battery may be at the end of its

life.

• The infrared wireless microphone's

power switch may be set to ON.

• Use a dedicated IR-200BT

rechargeable battery in the infrared
wireless microphone.

• Remove such foreign objects.

• Replace the rechargeable battery

with a new one.

• Detach the infrared wireless

microphone from the charger and
set the microphone power switch to
the OFF position, then reinsert the
microphone into the charger.

Summary of Contents for IR-200BC

Page 1: ...3 3 HANDLING PRECAUTIONS 3 4 NOMENCLATURE AND FUNCTIONS 4 5 CHARGING 5 6 TROUBLESHOOTING 7 7 SPECIFICATIONS 8 Accessories 8 Thank you for purchasing TOA s Battery Charger Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment TABLE OF CONTENTS ...

Page 2: ...als inside the battery charger or its infrared microphone receptacle as this may result in fire or electric shock Do not touch a power supply plug during thunder and lightning as this may result in electric shock Stop charging if the batteries are not fully charged within 3 hours Failure to do so may cause the batteries to fire explode leak or heat When Installing the Unit Never plug in nor remove...

Page 3: ...allowing up to 2 infrared wireless microphones to be fully charged within 3 hours 3 HANDLING PRECAUTIONS Since the supplied power cord is designed for use specifically with the IR 200BC charger do not use it with equipment other than the IR 200BC Use the IR 200BC in locations where an ambient temperature ranges from 0 to 40 ºC 32 to 104 ºF When cleaning the case be sure to first switch off the pow...

Page 4: ...frared wireless microphone receptacle Use the mounting adapter when charging the IR 200M microphone When charging the IR 300M microphone remove the mounting adapter and insert the microphone directly into the receptacle 6 Full charge indicator Lights green once the battery is fully charged 7 Charging indicator Lights red continuously while charging is in progress 8 Power input terminal Connect the...

Page 5: ...y If the battery operating time becomes extremely short even when it has been fully charged the battery has reached the end of its life and must be replaced Be sure to replace the battery with one designated for use with the microphone IR 200BT Tip Under normal use conditions the battery can cycle through approximately 500 charges and discharges after which it will usually need to be replaced Char...

Page 6: ...e the mounting adapter attached Insert the microphone into the hole in the adapter to charge For the IR 300M microphone Remove the mounting adapter to charge Refer to the figure at right Charging takes approximately 3 hours after which the full charge indicator lights green Step 6 Turn off the charger s power once charging is complete Notes Be sure to turn off the charger s power after charging is...

Page 7: ...ge 0 to 40 ºC or 32 to 104 ºF preventing charging Perform charging within the operating temperature range 0 to 40 ºC or 32 to 104 ºF Full charge indicator green always lights soon The dedicated IR 200BT rechargeable battery has probably reached the end of its life cycle usually after about 500 charges and discharges Replace the rechargeable battery with a new one Full charge indicator does not lig...

Page 8: ...of wireless 2 pieces 1 microphones to be charged simultaneously Operating Temperature 0 to 40 C 32 to 104 F Operating Humidity 30 to 85 RH Finish Case ABS resin metallic gray 50 gloss paint Microphone receptacle section PPE resin black Dimensions 238 w x 83 h 2 x 98 d mm 9 37 x 3 27 x 3 86 Weight 635 g or 1 4 lb charger with the mounting adapters attached Power cord 2 m or 6 56 ft 3 1 AC adapter D...

Reviews: