background image

133-07-272-70

URL:  http://www.toa.jp/

7. SPECIFICATIONS

Note:

The design and specifications are subject to change without notice for improvement. 

*

1

Using the mounting adapter allows one each of the IR-200M and IR-300M to be charged in combination. 

*

2

Height is 109.5 mm (4.31") when the mounting adapter is installed.

*

3

Not supplied with the IR-200BC KR. For the usable power supply cord and AC adapter, contact your
nearest TOA dealer.

• Accessories

Power Source

AC mains, 50/60 Hz (Power is supplied from the enclosed AC adapter.)

Current Consumption

Max. 2 A

Charging Time

Max. 3 hours

Number of wireless 

2 pieces*

1

microphones to be 
charged simultaneously

Operating Temperature 

0 to 40 °C (32 to 104 °F)

Operating Humidity

30 to 85% RH

Finish 

Case:

ABS resin, metallic gray, 50% gloss, paint

Microphone receptacle section: PPE resin, black

Dimensions 

238 (w) x 83 (h*

2

) x 98 (d) mm  (9.37" x 3.27" x 3.86") 

Weight 

635 g or 1.4 lb (charger with the mounting adapters attached)

Power cord (2 m or 6.56 ft)*

3

......................................................................... 1

AC adapter (DC cord length: 1.5 m or 4.92 ft)*

3

............................................ 1

Mounting adapter (pre-installed)  ................................................................... 2

Traceability Information for Europe (EMC directive 2004/108/EC)

Manufacturer:

TOA Corporation
7-2-1, Minatojima Nakamachi, Chuo-ku, Kobe, Hyogo, 
Japan

Authorized representative:

TOA Electronics Europe GmbH
Suederstrasse 282, 20537 Hamburg,
Germany

• Optional products

Rechargeable battery: IR-200BT-2 (containing 2 pieces)

Summary of Contents for IR-200BC

Page 1: ...3 3 HANDLING PRECAUTIONS 3 4 NOMENCLATURE AND FUNCTIONS 4 5 CHARGING 5 6 TROUBLESHOOTING 7 7 SPECIFICATIONS 8 Accessories 8 Thank you for purchasing TOA s Battery Charger Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment TABLE OF CONTENTS ...

Page 2: ...als inside the battery charger or its infrared microphone receptacle as this may result in fire or electric shock Do not touch a power supply plug during thunder and lightning as this may result in electric shock Stop charging if the batteries are not fully charged within 3 hours Failure to do so may cause the batteries to fire explode leak or heat When Installing the Unit Never plug in nor remove...

Page 3: ...allowing up to 2 infrared wireless microphones to be fully charged within 3 hours 3 HANDLING PRECAUTIONS Since the supplied power cord is designed for use specifically with the IR 200BC charger do not use it with equipment other than the IR 200BC Use the IR 200BC in locations where an ambient temperature ranges from 0 to 40 ºC 32 to 104 ºF When cleaning the case be sure to first switch off the pow...

Page 4: ...frared wireless microphone receptacle Use the mounting adapter when charging the IR 200M microphone When charging the IR 300M microphone remove the mounting adapter and insert the microphone directly into the receptacle 6 Full charge indicator Lights green once the battery is fully charged 7 Charging indicator Lights red continuously while charging is in progress 8 Power input terminal Connect the...

Page 5: ...y If the battery operating time becomes extremely short even when it has been fully charged the battery has reached the end of its life and must be replaced Be sure to replace the battery with one designated for use with the microphone IR 200BT Tip Under normal use conditions the battery can cycle through approximately 500 charges and discharges after which it will usually need to be replaced Char...

Page 6: ...e the mounting adapter attached Insert the microphone into the hole in the adapter to charge For the IR 300M microphone Remove the mounting adapter to charge Refer to the figure at right Charging takes approximately 3 hours after which the full charge indicator lights green Step 6 Turn off the charger s power once charging is complete Notes Be sure to turn off the charger s power after charging is...

Page 7: ...ge 0 to 40 ºC or 32 to 104 ºF preventing charging Perform charging within the operating temperature range 0 to 40 ºC or 32 to 104 ºF Full charge indicator green always lights soon The dedicated IR 200BT rechargeable battery has probably reached the end of its life cycle usually after about 500 charges and discharges Replace the rechargeable battery with a new one Full charge indicator does not lig...

Page 8: ...of wireless 2 pieces 1 microphones to be charged simultaneously Operating Temperature 0 to 40 C 32 to 104 F Operating Humidity 30 to 85 RH Finish Case ABS resin metallic gray 50 gloss paint Microphone receptacle section PPE resin black Dimensions 238 w x 83 h 2 x 98 d mm 9 37 x 3 27 x 3 86 Weight 635 g or 1 4 lb charger with the mounting adapters attached Power cord 2 m or 6 56 ft 3 1 AC adapter D...