5. CHARGING

Avoid charging microphones installed with rechargeable batteries
other than the dedicated IR-200BT battery. 
Charging any other than the specified battery could result in fire or
personal injury due to battery rupture.

CAUTION

Notes

• Use the charger in locations where the ambient temperature range is between 0 and 40 ºC (32 to 104 ºF).

• Charge the IR-200BT battery before using it. 

• If an infrared wireless microphone containing an IR-200BT battery has been stored for a long period of time,

it is recommended that the microphone be charged before use. 

• Avoid using the charger in locations subject to strong vibrations, as the resulting poor electrical contact may

prevent correct charging. 

• Do not frequently insert and remove the microphone from the charger during charging, as this could reduce

the number of times that the IR-200BT can be effectively charged and discharged.

• Rechargeable batteries are consumables and do not last indefinitely. If the battery operating time becomes

extremely short even when it has been fully charged, the battery has reached the end of its life and must be
replaced. Be sure to replace the battery with one designated for use with the microphone (IR-200BT).

Tip:

Under normal use conditions, the battery can cycle through approximately 500 charges and discharges,
after which it will usually need to be replaced.

Charger

Supplied power cord

Power switch

Power indicator

Full-charge 
indicator

Charging indicator

IR-200M (optional)

Mounting adapter
(pre-installed)

Power switch

IR-300M (optional)

Power input terminal

AC adapter plug

Bottom view of the charger

Cord

To AC wall outlet

Supplied AC adapter

1

1

2

3 ,  6

4

5

Handling the power cord

Step 1.

Connect the power cord to the AC adapter, then connect the AC adapter to the charger.
Once connected, push the cord into the slot in the charger's bottom surface to prevent the AC adapter
plug from accidentally slipping out of place. (Refer to "Handling the power cord" in the figure above.)

Step 2.

Insert the AC power plug into an AC wall outlet.

Step 3.

Set the charger's power switch to ON. 
Confirm that the power indicator is lit.

Summary of Contents for IR-200BC

Page 1: ...3 3 HANDLING PRECAUTIONS 3 4 NOMENCLATURE AND FUNCTIONS 4 5 CHARGING 5 6 TROUBLESHOOTING 7 7 SPECIFICATIONS 8 Accessories 8 Thank you for purchasing TOA s Battery Charger Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment TABLE OF CONTENTS ...

Page 2: ...als inside the battery charger or its infrared microphone receptacle as this may result in fire or electric shock Do not touch a power supply plug during thunder and lightning as this may result in electric shock Stop charging if the batteries are not fully charged within 3 hours Failure to do so may cause the batteries to fire explode leak or heat When Installing the Unit Never plug in nor remove...

Page 3: ...allowing up to 2 infrared wireless microphones to be fully charged within 3 hours 3 HANDLING PRECAUTIONS Since the supplied power cord is designed for use specifically with the IR 200BC charger do not use it with equipment other than the IR 200BC Use the IR 200BC in locations where an ambient temperature ranges from 0 to 40 ºC 32 to 104 ºF When cleaning the case be sure to first switch off the pow...

Page 4: ...frared wireless microphone receptacle Use the mounting adapter when charging the IR 200M microphone When charging the IR 300M microphone remove the mounting adapter and insert the microphone directly into the receptacle 6 Full charge indicator Lights green once the battery is fully charged 7 Charging indicator Lights red continuously while charging is in progress 8 Power input terminal Connect the...

Page 5: ...y If the battery operating time becomes extremely short even when it has been fully charged the battery has reached the end of its life and must be replaced Be sure to replace the battery with one designated for use with the microphone IR 200BT Tip Under normal use conditions the battery can cycle through approximately 500 charges and discharges after which it will usually need to be replaced Char...

Page 6: ...e the mounting adapter attached Insert the microphone into the hole in the adapter to charge For the IR 300M microphone Remove the mounting adapter to charge Refer to the figure at right Charging takes approximately 3 hours after which the full charge indicator lights green Step 6 Turn off the charger s power once charging is complete Notes Be sure to turn off the charger s power after charging is...

Page 7: ...ge 0 to 40 ºC or 32 to 104 ºF preventing charging Perform charging within the operating temperature range 0 to 40 ºC or 32 to 104 ºF Full charge indicator green always lights soon The dedicated IR 200BT rechargeable battery has probably reached the end of its life cycle usually after about 500 charges and discharges Replace the rechargeable battery with a new one Full charge indicator does not lig...

Page 8: ...of wireless 2 pieces 1 microphones to be charged simultaneously Operating Temperature 0 to 40 C 32 to 104 F Operating Humidity 30 to 85 RH Finish Case ABS resin metallic gray 50 gloss paint Microphone receptacle section PPE resin black Dimensions 238 w x 83 h 2 x 98 d mm 9 37 x 3 27 x 3 86 Weight 635 g or 1 4 lb charger with the mounting adapters attached Power cord 2 m or 6 56 ft 3 1 AC adapter D...

Reviews: