Chapter 3: wiring
3.2 Connection of MIC and extension unit
3.2 MIC add extension unit
When the IP remote control microphone RM-110 add the extension unit RM-110, using the extension cable
and bracket to make the connection.
[The requested hardware]
The RM-110 spare parts is included in the unit fittings.
Bracket A ............................................................................ 2
Bracket B ............................................................................. 1
Screw ................................................................................. 12
Step1:
turning over the IP-100RM and RM-110, putting them together.
Step 2
: connecting two units by extension cable
Step 3
: using the 4 screws to connect the two units (marked )
and bracket B.
Step 4:
using the 8 screws (remarked ) to connect
the two units and 2 brackets A, make the two units tightly.
Note:
•
Bracket A have two standby screw hole, if the appointed screw hole is damaged, thus use it to connect
the two units.
•
If you find incorrect or loose connection of the two units, screwing down all of screws, and taking part of
the two units, then connecting them with the screw.